Research Article
BibTex RIS Cite

Investigation of wear behavior of Ti-6Al-4V and AISI 316 L biomaterials with ball on disc test device

Year 2020, , 635 - 646, 15.06.2020
https://doi.org/10.24012/dumf.630224

Abstract

Ti-6Al-4V
material is generally used in biomaterial applications. However, this material
is difficult to supply and an expensive material. Instead of Ti-6Al-4V
material; It is investigated whether the use of 316 L material as an
alternative is easier and more economical. In this study, Ti-6Al-4V and AISI
316 L test specimens made of the material subjected to the test under the same
conditions wear performance were investigated using the ball on disc
experimental setup. The experiments were carried out in three replicates in a
dry and liquid medium. As a result, in the experiments; AISI 316 L samples are
coated with PVD method compared to other samples in wear rates and abrasive
wear marks on the surface of the samples were found to decrease. In studies
using sodium hyaluronate fluid, it was found that the rate of abrasion and wear
traces decreased compared to the dry environment. It was determined that 316 L
samples coated with PVD method showed better wear performance compared to
uncoated Ti-6Al-4V material.

References

  • 1. Gümüşderelioğlu, M. Metallic biomaterials. Science and Technical Journal 2002, July Issue, 4.
  • 2. Kohn, D. H. Metals in medical applications. Current Opinion in Solid State and Materials Science 1998, Vol. 3 (3), pp. 309-316.
  • 3. Alsaran, A. Determination of structural, mechanical and tribological properties of AISI 5140 steel applied to duplex surface treatment. Ph.D. Thesis, Ataturk University, Institute of Science and Technology, Erzurum, 2001.
  • 4. Janoss, B. PVD/CVD tool coatings enhance stamping & forming of stainless steels. Metal Forming (USA) 1999, Vol. 33 (3), pp. 110-112.
  • 5. Tokaji, K.; Ogawa, T.; Shibata, H. The effect of gas nitriding on fatigue behaviour in pure titanium. International journal of fatigue 1994, Vol. 16 (5), pp. 331-336.
  • 6. Zhao, Q.; Zhai, G.J.; Ng, D.; Zhang, X.Z.; Chen, Z.Q. Surface modification of Al 2 O 3 bioceramic by NH+ 2 ion implantation. Biomaterials 1999, Vol. 20 (6), pp. 595-599.
  • 7. Zhecheva, A.; Sha, W.; Malinov, S.; Long, A. Enhancing the microstructure and properties of titanium alloys through nitriding and other surface engineering methods. Surface and Coatings Technology 2005, Vol. 200 (7), pp. 2192-2207.
  • 8. Burg, T.; Standard, O. Materials for Biomedical Engineering. School of Materials Sciences and Engineering Universitz of New South Wales 2001.
  • 9. Çelik, İ.; Eroğlu, H. Selection application of material to be used in hip prosthesis production with analytic hierarchy process. Materialwissenschaft und Werkstofftechnik 2017, Vol. 48(11), pp. 1125-1132.
  • 10. Tas, A.C. Synthesis of biomimetic Ca-hydroxyapatite powders at 37 C in synthetic body fluids. Biomaterials 2000, Vol. 21 (14), pp. 1429-1438.
  • 11. Fouquet, V.; Pichon, L.; Drouet, M.; Straboni, A. Plasma assisted nitridation of Ti-6Al-4V. Applied Surface Science 2004, Vol. 221 (1), pp. 248-258.
  • 12. Lautenschlager, E.P.; Monaghan, P. Titanium and titanium alloys as dental materials. International dental journal 1993, Vol. 43 (3), pp. 245-253.
  • 13. Massiani, Y., Gravier, P., Crousier, J., Fedrizzi, L., Dapor, M.; Micheli, V.; Roux, L. Effects of ion beam implantation on the corrosion behaviour of TiN-coated Ti-6Al-4V alloy. Surface and Coatings Technology 1992, Vol. 52 (2), pp. 159-167.
  • 14. Berrı́os, J.; Teer, D.; Puchi-Cabrera, E. Fatigue properties of a 316L stainless steel coated with different TiN x deposits. Surface and Coatings Technology 2001, Vol. 148 (2), pp. 179-190.
  • 15. Borgioli, F.; Fossati, A;, Galvanetto, E.; Bacci, T. Glow-discharge nitriding of AISI 316L austenitic stainless steel: influence of treatment temperature. Surface and Coatings Technology 2005, Vol. 200 (7), pp. 2474-2480.
  • 16. Dogan, H.; Findik, F.; Morgul, O. Friction and wear behaviour of implanted AISI 316L SS and comparison with a substrate. Materials & design 2002, Vol. 23 (7), pp. 605-610.
  • 17. Fossati, A.; Borgioli, F.; Galvanetto, E.; Bacci, T. Corrosion resistance properties of glow-discharge nitrided AISI 316L austenitic stainless steel in NaCl solutions. Corrosion Science 2006, Vol. 48 (6), pp. 1513-1527.
  • 18. Sun, Y.; Bell, T. Sliding wear characteristics of low temperature plasma nitrided 316 austenitic stainless steel. Wear 1998, Vol. 218 (1), pp. 34-42.
  • 19. Feng, H.; Lee, S.; Hsu, C.; Ho, J. Study of high cycle fatigue of PVD surface-modified austempered ductile iron. Materials chemistry and physics 1999, Vol. 59 (2), pp. 154-161.
  • 20. Ranea, C. Wear resistance of thin coatings based on titanium. International Conference on Tribology 2002, Kayseri, pp. 15-18.
  • 21. Yi, Z.; Xiao, Z.; Ma, F.; Zhang, T.; Li, Y. Wear resistance properties of stainless steel modified with co-implantation of V+ C. Surface and Coatings Technology 2000, Vol. 128, pp. 186-191.

Ti-6Al-4V ve AISI 316 L biyomalzemelerin aşınma davranışlarının bilye disk deney düzeneği ile araştırılması

Year 2020, , 635 - 646, 15.06.2020
https://doi.org/10.24012/dumf.630224

Abstract

Ti-6Al-4V material is generally used in biomaterial applications. However, this material is difficult to supply and an expensive material. Instead of Ti-6Al-4V material; It is investigated whether the use of 316 L material as an alternative is easier and more economical. In this study, Ti-6Al-4V and AISI 316 L test specimens made of the material subjected to the test under the same conditions wear performance were investigated using the ball on disc experimental setup. The experiments were carried out in three replicates in a dry and liquid medium. As a result, in the experiments; AISI 316 L samples are coated with PVD method compared to other samples in wear rates and abrasive wear marks on the surface of the samples were found to decrease. In studies using sodium hyaluronate fluid, it was found that the rate of abrasion and wear traces decreased compared to the dry environment. It was determined that 316 L samples coated with PVD method showed better wear performance compared to uncoated Ti-6Al-4V material. Considering the density differences of Ti6Al4V and 316L materials, 316L can be used instead of Ti6Al4V material.

References

  • 1. Gümüşderelioğlu, M. Metallic biomaterials. Science and Technical Journal 2002, July Issue, 4.
  • 2. Kohn, D. H. Metals in medical applications. Current Opinion in Solid State and Materials Science 1998, Vol. 3 (3), pp. 309-316.
  • 3. Alsaran, A. Determination of structural, mechanical and tribological properties of AISI 5140 steel applied to duplex surface treatment. Ph.D. Thesis, Ataturk University, Institute of Science and Technology, Erzurum, 2001.
  • 4. Janoss, B. PVD/CVD tool coatings enhance stamping & forming of stainless steels. Metal Forming (USA) 1999, Vol. 33 (3), pp. 110-112.
  • 5. Tokaji, K.; Ogawa, T.; Shibata, H. The effect of gas nitriding on fatigue behaviour in pure titanium. International journal of fatigue 1994, Vol. 16 (5), pp. 331-336.
  • 6. Zhao, Q.; Zhai, G.J.; Ng, D.; Zhang, X.Z.; Chen, Z.Q. Surface modification of Al 2 O 3 bioceramic by NH+ 2 ion implantation. Biomaterials 1999, Vol. 20 (6), pp. 595-599.
  • 7. Zhecheva, A.; Sha, W.; Malinov, S.; Long, A. Enhancing the microstructure and properties of titanium alloys through nitriding and other surface engineering methods. Surface and Coatings Technology 2005, Vol. 200 (7), pp. 2192-2207.
  • 8. Burg, T.; Standard, O. Materials for Biomedical Engineering. School of Materials Sciences and Engineering Universitz of New South Wales 2001.
  • 9. Çelik, İ.; Eroğlu, H. Selection application of material to be used in hip prosthesis production with analytic hierarchy process. Materialwissenschaft und Werkstofftechnik 2017, Vol. 48(11), pp. 1125-1132.
  • 10. Tas, A.C. Synthesis of biomimetic Ca-hydroxyapatite powders at 37 C in synthetic body fluids. Biomaterials 2000, Vol. 21 (14), pp. 1429-1438.
  • 11. Fouquet, V.; Pichon, L.; Drouet, M.; Straboni, A. Plasma assisted nitridation of Ti-6Al-4V. Applied Surface Science 2004, Vol. 221 (1), pp. 248-258.
  • 12. Lautenschlager, E.P.; Monaghan, P. Titanium and titanium alloys as dental materials. International dental journal 1993, Vol. 43 (3), pp. 245-253.
  • 13. Massiani, Y., Gravier, P., Crousier, J., Fedrizzi, L., Dapor, M.; Micheli, V.; Roux, L. Effects of ion beam implantation on the corrosion behaviour of TiN-coated Ti-6Al-4V alloy. Surface and Coatings Technology 1992, Vol. 52 (2), pp. 159-167.
  • 14. Berrı́os, J.; Teer, D.; Puchi-Cabrera, E. Fatigue properties of a 316L stainless steel coated with different TiN x deposits. Surface and Coatings Technology 2001, Vol. 148 (2), pp. 179-190.
  • 15. Borgioli, F.; Fossati, A;, Galvanetto, E.; Bacci, T. Glow-discharge nitriding of AISI 316L austenitic stainless steel: influence of treatment temperature. Surface and Coatings Technology 2005, Vol. 200 (7), pp. 2474-2480.
  • 16. Dogan, H.; Findik, F.; Morgul, O. Friction and wear behaviour of implanted AISI 316L SS and comparison with a substrate. Materials & design 2002, Vol. 23 (7), pp. 605-610.
  • 17. Fossati, A.; Borgioli, F.; Galvanetto, E.; Bacci, T. Corrosion resistance properties of glow-discharge nitrided AISI 316L austenitic stainless steel in NaCl solutions. Corrosion Science 2006, Vol. 48 (6), pp. 1513-1527.
  • 18. Sun, Y.; Bell, T. Sliding wear characteristics of low temperature plasma nitrided 316 austenitic stainless steel. Wear 1998, Vol. 218 (1), pp. 34-42.
  • 19. Feng, H.; Lee, S.; Hsu, C.; Ho, J. Study of high cycle fatigue of PVD surface-modified austempered ductile iron. Materials chemistry and physics 1999, Vol. 59 (2), pp. 154-161.
  • 20. Ranea, C. Wear resistance of thin coatings based on titanium. International Conference on Tribology 2002, Kayseri, pp. 15-18.
  • 21. Yi, Z.; Xiao, Z.; Ma, F.; Zhang, T.; Li, Y. Wear resistance properties of stainless steel modified with co-implantation of V+ C. Surface and Coatings Technology 2000, Vol. 128, pp. 186-191.
There are 21 citations in total.

Details

Primary Language English
Journal Section Articles
Authors

Harun Akkuş 0000-0002-9033-309X

Tahsin Kamış This is me 0000-0003-2894-1809

Hayrettin Düzcükoğlu This is me 0000-0002-7016-6888

Publication Date June 15, 2020
Submission Date October 7, 2019
Published in Issue Year 2020

Cite

IEEE H. Akkuş, T. Kamış, and H. Düzcükoğlu, “Investigation of wear behavior of Ti-6Al-4V and AISI 316 L biomaterials with ball on disc test device”, DÜMF MD, vol. 11, no. 2, pp. 635–646, 2020, doi: 10.24012/dumf.630224.
DUJE tarafından yayınlanan tüm makaleler, Creative Commons Atıf 4.0 Uluslararası Lisansı ile lisanslanmıştır. Bu, orijinal eser ve kaynağın uygun şekilde belirtilmesi koşuluyla, herkesin eseri kopyalamasına, yeniden dağıtmasına, yeniden düzenlemesine, iletmesine ve uyarlamasına izin verir. 24456