Research Article
BibTex RIS Cite
Year 2021, , 543 - 550, 29.06.2021
https://doi.org/10.24012/dumf.949347

Abstract

References

  • TS EN ISO 3382-1: Acoustics - Measurement of Room Acoustic Parameters. Part 1 : Performance Spaces, 2009. M. Caliskan and Z. Sü Gül, “Acoustical design of Turkish Religious Affairs Mosque,” ICA 2013, 2013, no. 2-7 June.
  • Z. Karabiber and S. Erdogan, “Comparison of the Acoustical Properties of an Ancient and a Recent Mosque,” Forum Acusticum, 2002.
  • F. Bal Koçyiğit, “Evaluation of acoustic diversity of religious buildings; a case study from churches and mosques in Turkey,” 167th Acoustical Society of America Meeting, 2014.
  • N. N. Çelebi Şeker, “Salonların Mimari Tasarımının Erken Düşme Süresi ve Çınlama Süresi Akustik Parametrelerine Etkisi,” Megaron, vol. 16, no. 1, pp. 81–91, 2021.
  • E. Odabaş, Z. Sü Gül, and M. Çalışkan, “Doğramacızade Ali Pasha Camii’nin Akustik Ölçümlerle Değerlendirilmesi,” 9.Ulusal Akustik Kongresi.
  • H. Kuttruff, Room Acoustics, 5th ed. Abingdon: Oxon:Spon Press, 2009.
  • M. Sözen, Diyarbakır’da Türk Mimarisi. İstanbul, pp. 65,68,260, 1971.
  • M. B. Tanman, Fatih Pasha Camii maddesi, 12th ed. İstanbul: Türkiye Diyanet Vakfı İslam Ansiklopedisi, 1995.
  • İ. Yıldız, “Kurşunlu Camii Kompleksi Sanat Tarihi Raporu,” 2016.
  • Z. Boran, A, Erdal, “Diyarbakır’daki Osmanlı Dönemi Cami ve Mescidleri,” Diyarbakır Mimarisi, İ. Yıldız, Ed. Diyarbakır: Diyarbakır Valiliği Kültür ve Sanat Yayınları, 2011, pp. 257–264.
  • Vakıflar Genel Müdürlüğü (VGM) Arşivi, “Vakıflar Genel Müdürlüğü,” Diyarbakır, 1978.
  • F. Bal Koçyiğit, “Metro İstasyonlarinda Mezanin Katinda Ses Kaynaklarinin Araştirilmasi ve Çözümlenmesi,” Doktora tezi, Gazi Üniversitesi, Fen Bilimleri Enstitüsü, 2003.
  • A. Lawrence, Architectural Acoustics, no. 1932. Amsterdam-London-New York: Elsevier Publishing Company Limited, 1970.
  • Çevre ve Şehircilik Bakanlığı, “Çevresel Gürültünün Değerlendirilmesi ve Yönetimi Yönetmeliği,” Ankara, 2010.
  • E. Uysal, “Camilerde Mimari Akustik Tasarım Kriterleri ve Bir Örnek Çalışma: Hasan Tanık Camii,” Yüksek Lisans Tezi, Gazi Üniversitesi, Fen Bilimleri Enstitüsü 2015.
  • Z. S. Gül, M. Çalışkan, and A. Tavukçuoğlu, “Geçmişten Günümüze Süleymaniye Camii Akustiği,” Megaron, vol. 9, no. 3, pp. 201–216, 2014.

Assessment of the Acoustic Performance of Historical Structures That Shed Light on Today's Technologies: Fatih Pasha (Kurşunlu) Mosque - Diyarbakır

Year 2021, , 543 - 550, 29.06.2021
https://doi.org/10.24012/dumf.949347

Abstract

Today's technologies are produced using new construction methods and new materials and using different techniques. While the time dimension of the parametric design, which is defined as the fourth dimension, is sometimes an hour, day or year, sometimes this is seen as a bridge between the past and the present of the structures that have survived in a large date range. For this reason, the support of new building materials and techniques from time to time with methods that have the technical data of the period obtained as a result of our historical heritage and long experience can provide us with new perspectives. The architectural features and construction techniques of historical mosques contain important data on the acoustic performance of religious buildings. Our heritage knowledge must be blended with new knowledge and technologies. Within the scope of the study, the details and systems that were effective in providing acoustic performance parameters in the architecture of Fatih Pasha (Kurşunlu) Mosque, which was the first Ottoman period work of the city located in Diyarbakır Suriçi area, were examined. Among the objective parameters of the sound, Reverberation Time (RT), Early Decay Time (EDT), Clarity (C80), and Definition (D50) metrics were measured. The obtained data were compared with reference values and analyzed. As a result of the data and analysis obtained in the literature reviews, it was determined that the acoustic values of the mosque were in harmony with the reference values. When the measurement data were compared with the obtained international publications, it has been observed that the sound pressure value ranges depending on the frequency of acceptable indoor acoustics standards. The importance of restoration works in harmony with materials such as basalt, brick, limestone, lime mortar and plaster which are the original materials of the building was highlighted in terms of acoustics.

References

  • TS EN ISO 3382-1: Acoustics - Measurement of Room Acoustic Parameters. Part 1 : Performance Spaces, 2009. M. Caliskan and Z. Sü Gül, “Acoustical design of Turkish Religious Affairs Mosque,” ICA 2013, 2013, no. 2-7 June.
  • Z. Karabiber and S. Erdogan, “Comparison of the Acoustical Properties of an Ancient and a Recent Mosque,” Forum Acusticum, 2002.
  • F. Bal Koçyiğit, “Evaluation of acoustic diversity of religious buildings; a case study from churches and mosques in Turkey,” 167th Acoustical Society of America Meeting, 2014.
  • N. N. Çelebi Şeker, “Salonların Mimari Tasarımının Erken Düşme Süresi ve Çınlama Süresi Akustik Parametrelerine Etkisi,” Megaron, vol. 16, no. 1, pp. 81–91, 2021.
  • E. Odabaş, Z. Sü Gül, and M. Çalışkan, “Doğramacızade Ali Pasha Camii’nin Akustik Ölçümlerle Değerlendirilmesi,” 9.Ulusal Akustik Kongresi.
  • H. Kuttruff, Room Acoustics, 5th ed. Abingdon: Oxon:Spon Press, 2009.
  • M. Sözen, Diyarbakır’da Türk Mimarisi. İstanbul, pp. 65,68,260, 1971.
  • M. B. Tanman, Fatih Pasha Camii maddesi, 12th ed. İstanbul: Türkiye Diyanet Vakfı İslam Ansiklopedisi, 1995.
  • İ. Yıldız, “Kurşunlu Camii Kompleksi Sanat Tarihi Raporu,” 2016.
  • Z. Boran, A, Erdal, “Diyarbakır’daki Osmanlı Dönemi Cami ve Mescidleri,” Diyarbakır Mimarisi, İ. Yıldız, Ed. Diyarbakır: Diyarbakır Valiliği Kültür ve Sanat Yayınları, 2011, pp. 257–264.
  • Vakıflar Genel Müdürlüğü (VGM) Arşivi, “Vakıflar Genel Müdürlüğü,” Diyarbakır, 1978.
  • F. Bal Koçyiğit, “Metro İstasyonlarinda Mezanin Katinda Ses Kaynaklarinin Araştirilmasi ve Çözümlenmesi,” Doktora tezi, Gazi Üniversitesi, Fen Bilimleri Enstitüsü, 2003.
  • A. Lawrence, Architectural Acoustics, no. 1932. Amsterdam-London-New York: Elsevier Publishing Company Limited, 1970.
  • Çevre ve Şehircilik Bakanlığı, “Çevresel Gürültünün Değerlendirilmesi ve Yönetimi Yönetmeliği,” Ankara, 2010.
  • E. Uysal, “Camilerde Mimari Akustik Tasarım Kriterleri ve Bir Örnek Çalışma: Hasan Tanık Camii,” Yüksek Lisans Tezi, Gazi Üniversitesi, Fen Bilimleri Enstitüsü 2015.
  • Z. S. Gül, M. Çalışkan, and A. Tavukçuoğlu, “Geçmişten Günümüze Süleymaniye Camii Akustiği,” Megaron, vol. 9, no. 3, pp. 201–216, 2014.
There are 16 citations in total.

Details

Primary Language English
Journal Section Articles
Authors

Derya Çakır Aydın This is me 0000-0002-1376-8444

Filiz Bal Koçyiğit 0000-0003-4191-0724

Neslihan Dalkılıç 0000-0003-3920-9904

Publication Date June 29, 2021
Submission Date May 6, 2021
Published in Issue Year 2021

Cite

IEEE D. Çakır Aydın, F. Bal Koçyiğit, and N. Dalkılıç, “Assessment of the Acoustic Performance of Historical Structures That Shed Light on Today’s Technologies: Fatih Pasha (Kurşunlu) Mosque - Diyarbakır”, DÜMF MD, vol. 12, no. 3, pp. 543–550, 2021, doi: 10.24012/dumf.949347.
DUJE tarafından yayınlanan tüm makaleler, Creative Commons Atıf 4.0 Uluslararası Lisansı ile lisanslanmıştır. Bu, orijinal eser ve kaynağın uygun şekilde belirtilmesi koşuluyla, herkesin eseri kopyalamasına, yeniden dağıtmasına, yeniden düzenlemesine, iletmesine ve uyarlamasına izin verir. 24456