Research Article
BibTex RIS Cite

Unnecessary computed tomography and magnetic resonance imaging rates in a tertiary care hospital

Year 2017, Volume: 3 Issue: 1, 49 - 54, 04.03.2017
https://doi.org/10.18621/eurj.2017.5000196214

Abstract

Objective. The actual rate of unnecessary imaging is
unknown in our country. In this study we aimed to detect unnecessary computed tomography (CT)
and magnetic resonance imaging (MRI) rates and the radiological quality of
these examinations in our hospital. Methods. CT/MRI request documents of
1,713 patients who had multidetector CT or MRI examination in a 2-month period
at a single tertiary care hospital were obtained. We evaluated that whether the
disorder that mentioned in request document was present or not in multidetector
CT or MR images from the picture and archiving communicating system of our
hospital. Scoring was done as follows; score 0 (there is no pathologic
finding), score 1 (suspicious findings), and score 2 (presence of mentioned
pathology). The radiological quality of the examinations was scored as follows;
grade 0 (poor quality), grade 1 (moderate quality), and grade 2 (good quality).
Results.
There was not any pathologic finding in 35% of the patients included in the
study (score 0, unnecessary imaging). There was/were finding(s) regarding to
the disorder that mentioned in the request document in 43% of the patients
(score 2). Suspicious findings were existed in the remaining patients (score
1). In the assessment of radiologic quality of the examinations that included
in the study; 94% of the radiologic examinations had good quality and the
remaining had moderate (0.2%) and poor (5.5%) quality. Conclusions. Unnecessary
CT or MRI rate was detected as 35% in our hospital. Unnecessary imaging causes
increased nephrogenic systemic fibrosis, contrast-induced nephropathy and/or
radiation risks, and total cost. It may also cause reduced patient compliance
and prolongation of therapy period. 

References

  • [1] Gimbel RW, Fontelo P, Stephens MB, Olsen CH, Bunt C, Ledford CJ, et al. Radiation exposure and cost influence physician medical image decision making: a randomized controlled trial. Med Care 2013;51:628-32.
  • [2] Tosun O, Algin O, Yalcin N, Cay N, Ocakoglu G, Karaoglanoglu M. Ischiofemoral impingement: evaluation with new MRI parameters and assessment of their reliability. Skeletal Radiology 2012;41:575-87.
  • [3] Algin O, Ozmen E, Arslan H. Radiologic manifestations of colloid cysts: a pictorial essay. Can Assoc Radiol J 2013;64:56-60.
  • [4] Algin O, Evrimler S, Ozmen E, Metin M, Ersoy O, Karaoglanoglu M. Desmoid tumor associated with familial adenomatous polyposis: evaluation with 64-detector CT enterography. Iran J Radiol 2012;9:32-6.
  • [5] Kartal MG, Algin O. Evaluation of hydrocephalus and other cerebrospinal fluid disorders with MRI: an update. Insight imaging 2014;5:531-41.
  • [6] Algin O, Evrimler S, Ozmen E, Metin MR, Ersoy O, Karaoglanoglu M. A novel biphasic oral contrast solution for enterographic studies. J Comput Assist Tomogr 2013;37:65-74.
  • [7] Saadat S, Ghodsi SM, Firouznia K, Etminan M, Goudarzi K, Naieni KH. Overuse or underuse of MRI scanners in private radiology centers in Tehran. Int J Technol Assess Health Care 2008;24:277-81.
  • [8] The Ministry of Health of Turkey, Health statistics yearbook. 2013 http://sbu.saglik.gov.tr/Ekutuphane/kitaplar/health_statistics_yearbook_2013.pdf
  • [9] Crownover BK, Bepko JL. Appropriate and safe use of diagnostic imaging. Am Fam Physician 2013;87:494-501.
  • [10] The Ministry of Health of Turkey, Health statistics yearbook. 2013 http://ekutuphane.sagem.gov.tr/kitaplar/health_statistics_yearbook_2014.pdf
  • [11] Atac GK, Parmaksiz A, Inal T, Bulur E, Bulgurlu F, Oncu T, et al. Patient doses from CT examinations in Turkey. Diagn Interv Radiol 2015;21:428-34.
  • [12] Technical Report, Radiation sources in Turkey (Turkiye’de Radyasyon Kaynaklari) 2012 Available at: http://www.taek.gov.tr/belgeler-formlar/func-startdown/886/.
  • [13] Chen RC, Chu D, Lin HC, Chen T, Hung ST, Kuo NW. Association of hospital characteristics and diagnosis with the repeat use of CT and MRI: a nationwide population-based study in an Asian country. AJR Am J Roentgenol 2012;198:858-65.
  • [14] Ip IK, Mortele KJ, Prevedello LM, Khorasani R. Repeat abdominal imaging examinations in a tertiary care hospital. Am J Med 2012;125:155-61.
  • [15] Berrington de Gonzalez A, Mahesh M, Kim KP, Bhargavan M, Lewis R, Mettler F, et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 2009;169:2071-7.
  • [16] Sulagaesuan C, Saksobhavivat N, Asavaphatiboon S, Kaewlai R. Reducing emergency CT radiation doses with simple techniques: a quality initiative project. J Med Imaging Radiat Oncol 2016;60:23-34.
  • [17] IAEA. Radiation protection of patients (RPOP). Referring medical practitioners. https://rpop.iaea.org/RPOP/RPoP/Content/InformationFor/HealthProfessionals/6_OtherClinicalSpecialities/referring-medical-practitioners/index.htm
  • [18] Arslanoglu A, Bilgin S, Kubal Z, Ceyhan MN, Ilhan MN, Maral I. Doctors' and intern doctors' knowledge about patients' ionizing radiation exposure doses during common radiological examinations. Diagn Interv Radiol 2007;13:53-5.
  • [19] Bailey ED, Anderson V. Syllabus on radiography radiation protection. 6th revision, Sacramento, CA. https://www.cdph.ca.gov/pubsforms/Guidelines/Documents/RHB-RadiographySyllabus.pdf
  • [20] RSNA Syllabus for Biological Effects and Radiation Safety Associated with Imaging Modalities Updated 2011-12. https://rsna.org/RadioBiology_Syllabus.aspx
  • [21] Geenen RW, Kingma HJ, van der Molen AJ. Contrast-induced nephropathy: pharmacology, pathophysiology and prevention. Insights Imaging 2013;4:811-20.
  • [22] Prince MR, Zhang H, Morris M, MacGregor JL, Grossman ME, Silberzweig J, et al. Incidence of nephrogenic systemic fibrosis at two large medical centers. Radiology 2008;248:807-16.
  • [23] Algin O. A new contrast media for functional MR urography: Gd-MAG3. Med Hypotheses 2011;77:74-6.
Year 2017, Volume: 3 Issue: 1, 49 - 54, 04.03.2017
https://doi.org/10.18621/eurj.2017.5000196214

Abstract

References

  • [1] Gimbel RW, Fontelo P, Stephens MB, Olsen CH, Bunt C, Ledford CJ, et al. Radiation exposure and cost influence physician medical image decision making: a randomized controlled trial. Med Care 2013;51:628-32.
  • [2] Tosun O, Algin O, Yalcin N, Cay N, Ocakoglu G, Karaoglanoglu M. Ischiofemoral impingement: evaluation with new MRI parameters and assessment of their reliability. Skeletal Radiology 2012;41:575-87.
  • [3] Algin O, Ozmen E, Arslan H. Radiologic manifestations of colloid cysts: a pictorial essay. Can Assoc Radiol J 2013;64:56-60.
  • [4] Algin O, Evrimler S, Ozmen E, Metin M, Ersoy O, Karaoglanoglu M. Desmoid tumor associated with familial adenomatous polyposis: evaluation with 64-detector CT enterography. Iran J Radiol 2012;9:32-6.
  • [5] Kartal MG, Algin O. Evaluation of hydrocephalus and other cerebrospinal fluid disorders with MRI: an update. Insight imaging 2014;5:531-41.
  • [6] Algin O, Evrimler S, Ozmen E, Metin MR, Ersoy O, Karaoglanoglu M. A novel biphasic oral contrast solution for enterographic studies. J Comput Assist Tomogr 2013;37:65-74.
  • [7] Saadat S, Ghodsi SM, Firouznia K, Etminan M, Goudarzi K, Naieni KH. Overuse or underuse of MRI scanners in private radiology centers in Tehran. Int J Technol Assess Health Care 2008;24:277-81.
  • [8] The Ministry of Health of Turkey, Health statistics yearbook. 2013 http://sbu.saglik.gov.tr/Ekutuphane/kitaplar/health_statistics_yearbook_2013.pdf
  • [9] Crownover BK, Bepko JL. Appropriate and safe use of diagnostic imaging. Am Fam Physician 2013;87:494-501.
  • [10] The Ministry of Health of Turkey, Health statistics yearbook. 2013 http://ekutuphane.sagem.gov.tr/kitaplar/health_statistics_yearbook_2014.pdf
  • [11] Atac GK, Parmaksiz A, Inal T, Bulur E, Bulgurlu F, Oncu T, et al. Patient doses from CT examinations in Turkey. Diagn Interv Radiol 2015;21:428-34.
  • [12] Technical Report, Radiation sources in Turkey (Turkiye’de Radyasyon Kaynaklari) 2012 Available at: http://www.taek.gov.tr/belgeler-formlar/func-startdown/886/.
  • [13] Chen RC, Chu D, Lin HC, Chen T, Hung ST, Kuo NW. Association of hospital characteristics and diagnosis with the repeat use of CT and MRI: a nationwide population-based study in an Asian country. AJR Am J Roentgenol 2012;198:858-65.
  • [14] Ip IK, Mortele KJ, Prevedello LM, Khorasani R. Repeat abdominal imaging examinations in a tertiary care hospital. Am J Med 2012;125:155-61.
  • [15] Berrington de Gonzalez A, Mahesh M, Kim KP, Bhargavan M, Lewis R, Mettler F, et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 2009;169:2071-7.
  • [16] Sulagaesuan C, Saksobhavivat N, Asavaphatiboon S, Kaewlai R. Reducing emergency CT radiation doses with simple techniques: a quality initiative project. J Med Imaging Radiat Oncol 2016;60:23-34.
  • [17] IAEA. Radiation protection of patients (RPOP). Referring medical practitioners. https://rpop.iaea.org/RPOP/RPoP/Content/InformationFor/HealthProfessionals/6_OtherClinicalSpecialities/referring-medical-practitioners/index.htm
  • [18] Arslanoglu A, Bilgin S, Kubal Z, Ceyhan MN, Ilhan MN, Maral I. Doctors' and intern doctors' knowledge about patients' ionizing radiation exposure doses during common radiological examinations. Diagn Interv Radiol 2007;13:53-5.
  • [19] Bailey ED, Anderson V. Syllabus on radiography radiation protection. 6th revision, Sacramento, CA. https://www.cdph.ca.gov/pubsforms/Guidelines/Documents/RHB-RadiographySyllabus.pdf
  • [20] RSNA Syllabus for Biological Effects and Radiation Safety Associated with Imaging Modalities Updated 2011-12. https://rsna.org/RadioBiology_Syllabus.aspx
  • [21] Geenen RW, Kingma HJ, van der Molen AJ. Contrast-induced nephropathy: pharmacology, pathophysiology and prevention. Insights Imaging 2013;4:811-20.
  • [22] Prince MR, Zhang H, Morris M, MacGregor JL, Grossman ME, Silberzweig J, et al. Incidence of nephrogenic systemic fibrosis at two large medical centers. Radiology 2008;248:807-16.
  • [23] Algin O. A new contrast media for functional MR urography: Gd-MAG3. Med Hypotheses 2011;77:74-6.
There are 23 citations in total.

Details

Subjects Health Care Administration
Journal Section Original Articles
Authors

Mehmet Kilin This is me

Evrim Ozmen

Oktay Algin This is me

Publication Date March 4, 2017
Submission Date July 25, 2016
Acceptance Date November 19, 2016
Published in Issue Year 2017 Volume: 3 Issue: 1

Cite

AMA Kilin M, Ozmen E, Algin O. Unnecessary computed tomography and magnetic resonance imaging rates in a tertiary care hospital. Eur Res J. March 2017;3(1):49-54. doi:10.18621/eurj.2017.5000196214

e-ISSN: 2149-3189 


The European Research Journal, hosted by Turkish JournalPark ACADEMIC, is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

by-nc-nd.png