Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam

Year 2006, Volume: 19 Issue: 3, 163 - 172, 29.03.2010

Abstract

In this study, the corrosion of reinforced steel in the concrete samples with various concentrations of NaCl and with the addition of styrofoam which was replaced 15% of the aggregate volume in the concrete structure was investigated. Additionally, the change on the corrosion of steel in the concrete samples with styrofoam and/or with silica fume 10% in the cement volume was explored. Three groups of concrete samples containing various NaCl concentrations were prepared. In the first group, the  samples were without any additional material, the second group was produced by addition of styrofoam (15%) and the third group of samples prepared with the addition of styrofoam plus silica fume (10%). The corrosion rates were measured according to the galvanic current method on the samples. The corrosion potentials have been measured by applying the ASTM-C-876-91 method for 90 days and using Cu/CuSO4  reference electrode. As a result of these experiments, it was found that the corrosion rate of steel in the concrete samples with styrofoam increased with the increasing of the portion of NaCl. However, the corrosion rate of steel in the samples decreased with the addition of silica fume.

 

Key Words: Corrosion, Styrofoam, Silica fume, Reinforced concrete, Steel.

Year 2006, Volume: 19 Issue: 3, 163 - 172, 29.03.2010

Abstract

There are 0 citations in total.

Details

Primary Language English
Journal Section Civil Engineering
Authors

Oğuzhan Keleştemur

Servet Yıldız This is me

Publication Date March 29, 2010
Published in Issue Year 2006 Volume: 19 Issue: 3

Cite

APA Keleştemur, O., & Yıldız, S. (2010). Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam. Gazi University Journal of Science, 19(3), 163-172.
AMA Keleştemur O, Yıldız S. Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam. Gazi University Journal of Science. March 2010;19(3):163-172.
Chicago Keleştemur, Oğuzhan, and Servet Yıldız. “Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam”. Gazi University Journal of Science 19, no. 3 (March 2010): 163-72.
EndNote Keleştemur O, Yıldız S (March 1, 2010) Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam. Gazi University Journal of Science 19 3 163–172.
IEEE O. Keleştemur and S. Yıldız, “Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam”, Gazi University Journal of Science, vol. 19, no. 3, pp. 163–172, 2010.
ISNAD Keleştemur, Oğuzhan - Yıldız, Servet. “Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam”. Gazi University Journal of Science 19/3 (March 2010), 163-172.
JAMA Keleştemur O, Yıldız S. Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam. Gazi University Journal of Science. 2010;19:163–172.
MLA Keleştemur, Oğuzhan and Servet Yıldız. “Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam”. Gazi University Journal of Science, vol. 19, no. 3, 2010, pp. 163-72.
Vancouver Keleştemur O, Yıldız S. Effect of Various NaCl Concentration on Corrosion of Steel in Concrete Produced by Addition of Styrofoam. Gazi University Journal of Science. 2010;19(3):163-72.