BibTex RIS Cite

-

Year 2015, Volume: 6 Issue: 2, 159 - 164, 10.07.2015
https://doi.org/10.5799/ahinjs.01.2015.02.0509

Abstract

Objective: The intra-coronary stents provided great benefit after percutaneous transluminal coronary angioplasty (PTCA); however, high in-stent restenosis rates, even up to 25-30%, is the the main concern. Cytotoxic drug-eluting stents were developed to overcome this challenge. Whereas, they interfered vessel healing and endothelization process which led to increased risk of stent thrombosis. A bioinert molecule, polyzene-F(PzF), was applied to the surface of a new generation stent to provide anti-inflammatory and antithrombogenic property. We aimed to compare the sirolimuseluting stent with PzF-coated cobalt-chrome stent in terms of early inflammatory response and long-term major adverse cardiac events (MACE) rates. Methods: Stable coronary artery disease patients treated with PzF-coated cobalt-chrome stent formed the 1st group (n=19), and those received sirolimus-eluting stent (n=13) formed the 2nd group. Serum hsCRP and IL-6 levels were measured before percutaneous coronary intervention (prePCI), and after 1st and 10th days (post-PCI 1, and post-PCI 10, respectively) of PCI. The patients were followed-up to 1 year in terms of MACE experience.Results: The study groups were comparable in terms of pre-PCI, post-PCI-1 and post-PCI-10 serum hsCRP and IL-6 levels. Four of 19 patients (21%) in the 1st group and 1 of 13 patients (8%) in the 2nd group experienced MACE during 1-year follow-up; whereas this difference was not statistically significant (p=0.26).Conclusion: Although, the PzF-coated cobalt-chrome stent was claimed to have lower anti-inflammatory and antithrombogenic properties, we showed similar inflammatory response and long-term MACE rates compared to sirolimuseluting stent. Prospective, randomized, large scale studies are needed to clarify this issue. J Clin Exp Invest 2015; 6 (2)

References

  • 1. Serruys PW, Degertekin M, Tanabe K, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting Velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation 2002;106:798-803.
  • 2. Richter GM, Stampfl U, Stampfl S, et al. A new polymer concept for coating of vascular stents using PTFEP (poly(bis(trifluoroethoxy)phosphazene) to reduce thrombogenicity and late in-stent stenosis. Invest Radiol 2005;40:210-218.
  • 3. Hill RA, Boland A, Dickson R, et al. Drug-eluting stents: a systematic review and economic evaluation. Health Technol Assess 2007, 11:iii, xi-221.
  • 4. Fajadet J, Wijns W, Laarman GJ, et al. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation 2006;114:798-806

Sirolimus-kaplı stent ile polizen-F polimerli kobalt krom stentin erken dönemde tetiklediği inflamatuvar yanıt ve uzun dönem sonuçlarının karşılaştırılması

Year 2015, Volume: 6 Issue: 2, 159 - 164, 10.07.2015
https://doi.org/10.5799/ahinjs.01.2015.02.0509

Abstract

Amaç: Perkütan translüminal koroner anjioplasti (PTCA) işleminin erken ve geç dönem sonuçlarında çok önemli iyileşmeler sağlayan stentler ile geç dönemde karşılaşılan en önemli sorun %25-30’lara varan restenoz oranları olmuştur. Bunun üstesinden gelmek için geliştirilen ilaç kaplı stentler (DES), restenoz oranlarını azaltmakla birlikte damar iyileşmesini ve endotelizasyonu bozduğundan stent trombozu riskini önemli ölçüde artırmıştır. Biyoinert bir molekül olan Polizen-F (PzF) polimerleriyle yüzey modifikasyonu uygulanmış yeni nesil stentler anti-inflamatuvar ve anti-trombojenik özelliklerini vurgulayarak piyasaya sürülmüştür. Bu çalışmada PzF polimeriyle kaplı stent ile sirolimus kaplı stent takılan hastaları, erken dönemdeki inflamatuvar yanıtları ve 1 yıllık takipte görülen majör istenmeyen kardiyak olay (MACE) sıklığı bakımından karşılaştırmayı amaçladık.

Yöntemler: Stabil koroner arter hastalığı (KAH) tanısıyla PzF polimeri kaplı stent takılan hastalar 1.grubu (n=19), sirolimus kaplı stent takılan hastalar 2.gurubu (n=13) oluşturdu. Hastalardan perkütan koroner girişim (PKG) öncesi (pre-PKG), işlem sonrası 1. ve 10.günde (post-PKG 1. ve post-PKG 10.gün) hsCRP ve IL-6 düzeyi bakıldı. Hastalar ortalama 1 yıl süreyle gelişebilecek MACE sıklığı açısından takip edildi.

Bulgular: Pre-PKG, post-PKG 1. ve 10.gündeki hsCRP ve IL-6 düzeyleri bakımından gruplar arasında anlamlı bir fark yoktu. 1.gruptaki19 hastadan 4’ünde (%21) MACE gelişirken, bu oran 2.grupta 13 hastada 1 idi (%8); fakat gruplar arasındaki bu fark istatistiksel olarak anlamlı değildi (p=0,26).

Sonuç: Daha az inflamatuvar yanıtı tetiklediği ve anti-trombojenik özelliği iddiasıyla piyasaya sürülen PzF polimeriyle kaplı stent ile sirolimus-kaplı stent arasında tetikledikleri inflamatuvar yanıt belirteçleri ve 1-yıllık MACE oranları bakımından anlamlı bir fark gözlenmedi. Bu konunun aydınlatılması için prospektif, randomize, büyük ölçekli çalışmalara ihtiyaç vardır.

Anahtar kelimeler: Koroner arter hastalığı, polizen-F, sirolimus-kaplı stent, stent trombozu, stent-içi restenoz

References

  • 1. Serruys PW, Degertekin M, Tanabe K, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting Velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation 2002;106:798-803.
  • 2. Richter GM, Stampfl U, Stampfl S, et al. A new polymer concept for coating of vascular stents using PTFEP (poly(bis(trifluoroethoxy)phosphazene) to reduce thrombogenicity and late in-stent stenosis. Invest Radiol 2005;40:210-218.
  • 3. Hill RA, Boland A, Dickson R, et al. Drug-eluting stents: a systematic review and economic evaluation. Health Technol Assess 2007, 11:iii, xi-221.
  • 4. Fajadet J, Wijns W, Laarman GJ, et al. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation 2006;114:798-806
There are 4 citations in total.

Details

Primary Language Turkish
Journal Section Research Article
Authors

Murat Yuksel

Zeki Şimşek This is me

Göksel Açar This is me

Ulaankhuu Batgerel This is me

Hacı Güneş This is me

Ali Esen This is me

Mehmet Türkmen This is me

Publication Date July 10, 2015
Published in Issue Year 2015 Volume: 6 Issue: 2

Cite

APA Yuksel, M., Şimşek, Z., Açar, G., Batgerel, U., et al. (2015). Sirolimus-kaplı stent ile polizen-F polimerli kobalt krom stentin erken dönemde tetiklediği inflamatuvar yanıt ve uzun dönem sonuçlarının karşılaştırılması. Journal of Clinical and Experimental Investigations, 6(2), 159-164. https://doi.org/10.5799/ahinjs.01.2015.02.0509
AMA Yuksel M, Şimşek Z, Açar G, Batgerel U, Güneş H, Esen A, Türkmen M. Sirolimus-kaplı stent ile polizen-F polimerli kobalt krom stentin erken dönemde tetiklediği inflamatuvar yanıt ve uzun dönem sonuçlarının karşılaştırılması. J Clin Exp Invest. July 2015;6(2):159-164. doi:10.5799/ahinjs.01.2015.02.0509
Chicago Yuksel, Murat, Zeki Şimşek, Göksel Açar, Ulaankhuu Batgerel, Hacı Güneş, Ali Esen, and Mehmet Türkmen. “Sirolimus-Kaplı Stent Ile Polizen-F Polimerli Kobalt Krom Stentin Erken dönemde tetiklediği Inflamatuvar yanıt Ve Uzun dönem sonuçlarının karşılaştırılması”. Journal of Clinical and Experimental Investigations 6, no. 2 (July 2015): 159-64. https://doi.org/10.5799/ahinjs.01.2015.02.0509.
EndNote Yuksel M, Şimşek Z, Açar G, Batgerel U, Güneş H, Esen A, Türkmen M (July 1, 2015) Sirolimus-kaplı stent ile polizen-F polimerli kobalt krom stentin erken dönemde tetiklediği inflamatuvar yanıt ve uzun dönem sonuçlarının karşılaştırılması. Journal of Clinical and Experimental Investigations 6 2 159–164.
IEEE M. Yuksel, Z. Şimşek, G. Açar, U. Batgerel, H. Güneş, A. Esen, and M. Türkmen, “Sirolimus-kaplı stent ile polizen-F polimerli kobalt krom stentin erken dönemde tetiklediği inflamatuvar yanıt ve uzun dönem sonuçlarının karşılaştırılması”, J Clin Exp Invest, vol. 6, no. 2, pp. 159–164, 2015, doi: 10.5799/ahinjs.01.2015.02.0509.
ISNAD Yuksel, Murat et al. “Sirolimus-Kaplı Stent Ile Polizen-F Polimerli Kobalt Krom Stentin Erken dönemde tetiklediği Inflamatuvar yanıt Ve Uzun dönem sonuçlarının karşılaştırılması”. Journal of Clinical and Experimental Investigations 6/2 (July 2015), 159-164. https://doi.org/10.5799/ahinjs.01.2015.02.0509.
JAMA Yuksel M, Şimşek Z, Açar G, Batgerel U, Güneş H, Esen A, Türkmen M. Sirolimus-kaplı stent ile polizen-F polimerli kobalt krom stentin erken dönemde tetiklediği inflamatuvar yanıt ve uzun dönem sonuçlarının karşılaştırılması. J Clin Exp Invest. 2015;6:159–164.
MLA Yuksel, Murat et al. “Sirolimus-Kaplı Stent Ile Polizen-F Polimerli Kobalt Krom Stentin Erken dönemde tetiklediği Inflamatuvar yanıt Ve Uzun dönem sonuçlarının karşılaştırılması”. Journal of Clinical and Experimental Investigations, vol. 6, no. 2, 2015, pp. 159-64, doi:10.5799/ahinjs.01.2015.02.0509.
Vancouver Yuksel M, Şimşek Z, Açar G, Batgerel U, Güneş H, Esen A, Türkmen M. Sirolimus-kaplı stent ile polizen-F polimerli kobalt krom stentin erken dönemde tetiklediği inflamatuvar yanıt ve uzun dönem sonuçlarının karşılaştırılması. J Clin Exp Invest. 2015;6(2):159-64.