Purpose: The aim of this study was to investigate the micro tensile bond strength of a self-etch adhesive system following 1 year storage in water.
Materials and Methods: 10 sound human molar teeth were used for micro tensile bond strength test. Two-step self-etch dentin adhesive (Clearfil SE Bond®) was applied to the flat dentin surfaces according to the manufacturer’s instructions. Composite blocks (Z-250; 3M ESPE) of 5 mm in height have been prepared by using layering technique. Teeth were stored in water for 24 hours at 37°C and longitudinally sectioned to obtain dentin sticks of 1 mm2.. Randomly selected samples from half of the teeth were immediately subjected to micro tensile test and). Remaining specimens were tested after 1 year storage in water. Bond strengths were calculated in megapascal (MPa).
Results: Means and standard deviations of the Clearfil SE Bond® micro tensile bond strength values were, respectively, 37.31 ± 13.77 MPa and 24.78 ± 2.99 MPa after 24 h and 1 year of storage in water. The difference was statistically significant (p=0,031).
Conclusion: Long-term storage in water decreased the micro tensile bond strength values of the two-step self-etch adhesive which has been accepted as the gold standard in bond strength tests.
Purpose: The aim of this study was to investigate the micro tensile bond strength of a self-etch etch dentin bağlayıcı sistemin 1 yıl suda bekletme adhesive system following 1 year storage in water. sonucunda bağlanma dayanım değerlerindeki Materials and Methods: 10 sound human molar teeth were used for micro tensile bond strength test. Twostep self-etch dentin adhesive (Clearfil SE Bond®) was applied to the flat dentin surfaces according to the manufacturer’s instructions. Composite blocks (Z250; 3M ESPE) of 5 mm in height have been prepared by using layering technique. Teeth were stored in water for 24 hours at 37°C and longitudinally sectioned to obtain dentin sticks of 1 mm2.Randomly selected samples from half of the teeth were immediately subjected to micro tensile test and. Remaining seçilen 5 dişe ait çubuklar 24 saat sonra, kalan specimens were tested after 1 year storage in water. 5 dişten hazırlanan çubuklar ise 1 yıl 37°C suda Bond strengths were calculated in megapascal (MPa).Results: Means and standard deviations of the Elde edilen bağlanma dayanımı değerleri megapascal Clearfil SE Bond® micro tensile bond strength values were, respectively, 37.31 ± 13.77 MPa and 24.78 ± (MPa) olarak kayıt edilmiştir
Primary Language | English |
---|---|
Subjects | Health Care Administration |
Journal Section | Original Research Articles |
Authors | |
Publication Date | May 18, 2015 |
Published in Issue | Year 2015 Volume: 49 Issue: 2 |