Review
BibTex RIS Cite

T1 and T2 Mapping in Cardiac MRI

Year 2020, Volume: 2 Issue: 2, 140 - 142, 31.12.2020

Abstract

In the recent years, according to the development in magnetic resonance imaging (MRI) , the parallel imaging techniques such as T1 and T2 mapping have been the guide for diagnosis. Mapping technics give ideas about tissue characterization. In this review, we mention about T1 and T2 mapping in cardiac MRI.

References

  • Referans1. Messroghli DR, Radjenovic A, Kozerke S, Higgins DM, Sivananthan MU, Ridgway JP. Modified look-locker inversion re- covery (MOLLI) for high-resolution T 1 mapping of the heart. Magn Reson Med. 2004;52:141–6. https://doi.org/10.1002/mrm. 20110.
  • Referans2. Huang TY, Liu YJ, Stemmer A, Poncelet BP. T2 measurement of the human myocardium using a T 2-prepared transient-state trueFISP sequence. Magn Reson Med. 2007;57:960–6. https://doi. org/10.1002/mrm.21208.
  • Referans3. Moon JC, Messroghli DR, Kellman P, et al. Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Mag- netic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement. J Cardiovasc Magn Reson 2013;15:92.
  • Referans4. Nacif MS, Turkbey EB, Gai N, et al. Myocardial T1 mapping with MRI: comparison of look-locker and MOLLI sequences. J Magn Reson Imaging 2011;34:1367–73.
  • Referans5. Dabir D, Child N, Kalra A, Rogers T, Gebker R, Jabbour A, et al. Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 multicenter cardiovascular magnetic resonance study. J Cardiovasc Magn Reson 2014;16:69
  • Referans6. Messroghli DR, Walters K, Plein S, et al. Myocardial T1 mapping: application to patients with acute and chronic myocardial infarc- tion. Magn Reson Med 2007; 58: 34-40.
  • Referans7. Fernandez-Jimenez R, Sanchez-Gonzalez J, Aguero J, et al. Fast T2 gradient-spin-echo (T2- GraSE) mapping for myocardial edema quantifica- tion: first in vivo validation in a porcine model of ischemia/reperfusion. J Cardiovasc Magn Reson 2015;17:92.
  • Referans8. Hinojar R, Varma N, Child N, et al. T1 mapping in discrimination of hypertrophic phenotypes: hypertensive heart disease and hyper- trophic cardiomyopathy: findings from the International T1 Multi- center Cardiovascular Magnetic Resonance study. Circ Cardiovasc Imaging 2015; 8: e003285.
  • Referans9. Hinojar R, Nagel E, Puntmann VO. T1 mapping in myocarditis: headway to a new era for cardiovascu- lar magnetic resonance. Expert Rev Cardiovasc Ther 2015;13(8):871–4.
  • Referans10. Sado DM, Flett AS, Moon JC. Novel imaging techniques for diffuse myocardial fibrosis. Future Cardiol. 2011; 7(5):643–50.
  • Referans11. Pica S, Sado DM, Maestrini V, et al. Repro- ducibility of native myocardial T1 mapping in the assessment of Fabry disease and its role in early detection of cardiac involvement by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2014;16:99.
  • Referans12. Sado DM, Maestrini V, Piechnik SK, Banypersad SM, White SK, Flett AS, et al. Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload. J Magn Reson Imaging 2015;41:1505-1511
  • Referans13. von Knobelsdorff-Brenkenhoff F, Prothmann M, Dieringer MA, Wassmuth R, Greiser A, Schwenke C, et al: Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications. J Cardiovasc Magn Reson 2013;15:53.
  • Referans14. Pathik B, Raman B, Mohd Amin NH, et al. Troponin-positive chest pain with unobstructed coronary arteries: Incremental diagnostic value of car- diovascular magnetic resonance imaging. Eur Heart J Cardiovasc Imag- ing 2016;17:1146–1152.
  • Referans15. Jeserich M, Föll D, Olschewski M, Kimmel S, Friedrich MG, Bode C, et al. Evidence of myocardial edema in patients with nonischemic dilated cardiomyopathy. Clin Cardiol 2012;35:371-376
  • Referans16. Carpenter JP, He T, Kirk P, et al. On T2* magnetic resonance and cardiac iron. Circulation 2011;123:1519–28.

Kardiyak MRI da T1 ve T2 haritalama

Year 2020, Volume: 2 Issue: 2, 140 - 142, 31.12.2020

Abstract

In the recent years, according to the development in magnetic resonance imaging (MRI) , the parallel imaging techniques such as T1 and T2 mapping have been the guide for diagnosis. Mapping technics give ideas about tissue characterization. In this review, we mention about T1 and T2 mapping in cardiac MRI.

References

  • Referans1. Messroghli DR, Radjenovic A, Kozerke S, Higgins DM, Sivananthan MU, Ridgway JP. Modified look-locker inversion re- covery (MOLLI) for high-resolution T 1 mapping of the heart. Magn Reson Med. 2004;52:141–6. https://doi.org/10.1002/mrm. 20110.
  • Referans2. Huang TY, Liu YJ, Stemmer A, Poncelet BP. T2 measurement of the human myocardium using a T 2-prepared transient-state trueFISP sequence. Magn Reson Med. 2007;57:960–6. https://doi. org/10.1002/mrm.21208.
  • Referans3. Moon JC, Messroghli DR, Kellman P, et al. Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Mag- netic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement. J Cardiovasc Magn Reson 2013;15:92.
  • Referans4. Nacif MS, Turkbey EB, Gai N, et al. Myocardial T1 mapping with MRI: comparison of look-locker and MOLLI sequences. J Magn Reson Imaging 2011;34:1367–73.
  • Referans5. Dabir D, Child N, Kalra A, Rogers T, Gebker R, Jabbour A, et al. Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 multicenter cardiovascular magnetic resonance study. J Cardiovasc Magn Reson 2014;16:69
  • Referans6. Messroghli DR, Walters K, Plein S, et al. Myocardial T1 mapping: application to patients with acute and chronic myocardial infarc- tion. Magn Reson Med 2007; 58: 34-40.
  • Referans7. Fernandez-Jimenez R, Sanchez-Gonzalez J, Aguero J, et al. Fast T2 gradient-spin-echo (T2- GraSE) mapping for myocardial edema quantifica- tion: first in vivo validation in a porcine model of ischemia/reperfusion. J Cardiovasc Magn Reson 2015;17:92.
  • Referans8. Hinojar R, Varma N, Child N, et al. T1 mapping in discrimination of hypertrophic phenotypes: hypertensive heart disease and hyper- trophic cardiomyopathy: findings from the International T1 Multi- center Cardiovascular Magnetic Resonance study. Circ Cardiovasc Imaging 2015; 8: e003285.
  • Referans9. Hinojar R, Nagel E, Puntmann VO. T1 mapping in myocarditis: headway to a new era for cardiovascu- lar magnetic resonance. Expert Rev Cardiovasc Ther 2015;13(8):871–4.
  • Referans10. Sado DM, Flett AS, Moon JC. Novel imaging techniques for diffuse myocardial fibrosis. Future Cardiol. 2011; 7(5):643–50.
  • Referans11. Pica S, Sado DM, Maestrini V, et al. Repro- ducibility of native myocardial T1 mapping in the assessment of Fabry disease and its role in early detection of cardiac involvement by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2014;16:99.
  • Referans12. Sado DM, Maestrini V, Piechnik SK, Banypersad SM, White SK, Flett AS, et al. Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload. J Magn Reson Imaging 2015;41:1505-1511
  • Referans13. von Knobelsdorff-Brenkenhoff F, Prothmann M, Dieringer MA, Wassmuth R, Greiser A, Schwenke C, et al: Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications. J Cardiovasc Magn Reson 2013;15:53.
  • Referans14. Pathik B, Raman B, Mohd Amin NH, et al. Troponin-positive chest pain with unobstructed coronary arteries: Incremental diagnostic value of car- diovascular magnetic resonance imaging. Eur Heart J Cardiovasc Imag- ing 2016;17:1146–1152.
  • Referans15. Jeserich M, Föll D, Olschewski M, Kimmel S, Friedrich MG, Bode C, et al. Evidence of myocardial edema in patients with nonischemic dilated cardiomyopathy. Clin Cardiol 2012;35:371-376
  • Referans16. Carpenter JP, He T, Kirk P, et al. On T2* magnetic resonance and cardiac iron. Circulation 2011;123:1519–28.
There are 16 citations in total.

Details

Primary Language Turkish
Subjects Clinical Sciences
Journal Section Review
Authors

Nevin Aydın 0000-0002-7765-4323

Publication Date December 31, 2020
Published in Issue Year 2020 Volume: 2 Issue: 2

Cite

APA Aydın, N. (2020). Kardiyak MRI da T1 ve T2 haritalama. Journal of Medical Innovation and Technology, 2(2), 140-142.
AMA Aydın N. Kardiyak MRI da T1 ve T2 haritalama. Journal of Medical Innovation and Technology. December 2020;2(2):140-142.
Chicago Aydın, Nevin. “Kardiyak MRI Da T1 Ve T2 Haritalama”. Journal of Medical Innovation and Technology 2, no. 2 (December 2020): 140-42.
EndNote Aydın N (December 1, 2020) Kardiyak MRI da T1 ve T2 haritalama. Journal of Medical Innovation and Technology 2 2 140–142.
IEEE N. Aydın, “Kardiyak MRI da T1 ve T2 haritalama”, Journal of Medical Innovation and Technology, vol. 2, no. 2, pp. 140–142, 2020.
ISNAD Aydın, Nevin. “Kardiyak MRI Da T1 Ve T2 Haritalama”. Journal of Medical Innovation and Technology 2/2 (December 2020), 140-142.
JAMA Aydın N. Kardiyak MRI da T1 ve T2 haritalama. Journal of Medical Innovation and Technology. 2020;2:140–142.
MLA Aydın, Nevin. “Kardiyak MRI Da T1 Ve T2 Haritalama”. Journal of Medical Innovation and Technology, vol. 2, no. 2, 2020, pp. 140-2.
Vancouver Aydın N. Kardiyak MRI da T1 ve T2 haritalama. Journal of Medical Innovation and Technology. 2020;2(2):140-2.