Research Article
BibTex RIS Cite

Electromyographic features of intermittent intraoperative neuromonitorization in the thyroid surgery

Year 2020, Volume: 8 Issue: 2, 131 - 137, 23.08.2020
https://doi.org/10.37696/nkmj.719020

Abstract

Background: The aims of this study are, to summarize the trick points of intermittent intraoperative neuromonitoring(I-IONM), outlines of electrophysiologic outcomes of electromyography(EMG), and to determine the electrophysiological properties of left and right recurrent laryngeal nerve(RLN) which anatomical lengths are different from each other.
Material Method: 34 thyroidectomy cases(27 of total thyroidectomy, 7 of hemithyroidectomy) with use of I-IONM, between June 2016 and June 2017 were retrospectively examined. Predissection(R1, V1) and postdissection(R2, V2) EMG waveforms of the right and left sides' vagal nerve (VN) and RLN were evaluated.
Results: There were 29 females and 5 males patients with mean age of 43.85±13.86 years. 61 nerves at risk were successfully evaluated with I-IONM. Mean R1 and R2 amplitudes of the right RLN were 280±10 µV and 270±9µV; the left RLN were 270±10µV and 260±9µV respectively. Mean V1 and V2 amplitudes of the right VN were 210±7µV and 190±7µV; the left VN were 190±5.4µV and 170±5µV respectively. Mean R1 and R2 latencies of the right RLN were 2.03±0.42mS and 2.0±0.46mS; the left RLN were 1.90 ± 0.30mS and 1.96 ± 0.33mS respectively. Mean V1 and V2 latencies of the right VN were 1.91±0.46mS and 1.82±0.52mS; the left VN were 2.01±0.34mS and 2.07±0.38mS respectively. There was no statistically significant difference between the sides in terms of electromyographic waveforms of the VN and RLN.
Conclusion: The left RLN has a longer anatomical length than the right RLN but we concluded that the length of the nerve does not affect the amplitude and latency.

References

  • 1. Calò PG, Pisano G, Medas F, Pittau MR, Gordini L, Demontis R, et al. Identification alone versus intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery: experience of 2034 consecutive patients. J Otolaryngol Head Neck Surg. 2014;43(1):16. 2. Sun H, Tian W, Jiang K, Chiang F, Wang P, Huang T, et al. Clinical guidelines on intraoperative neuromonitoring during thyroid and parathyroid surgery. Ann Transl Med. 2015;3(15):213. 3. Flisberg K, Lindholm T. Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol Suppl. 1969;263:63–7. 4. Caruso E, Pino A, Dionigi G, Pontin A. Safety of intraoperative neuromonitoring. Ann Thyroid. 2019;4:6. 5. Deniwar A, Kandil E, Randolph G. Electrophysiological neural monitoring of the laryngeal nerves in thyroid surgery: review of the current literature. Gland Surg. 2015;4(5):368–75. 6. Dralle H, Sekulla C, Lorenz K, Brauckhoff M, Machens A; German IONM Study Group. Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery. World J Surg. 2008;32(7):1358–66. 7. Chiang FY, Lee KW, Chen HC, Chen HY, Lu IC, Kuo WR, et al. Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World J Surg. 2010;34(2):223–9. 8. Mermelstein M, Von Weiler R, Rubinstein E. Intraoperative identification of laryngeal nerves with laryngeal electromyography. Laryngoscope. 1996;106:752–6. 9. Lorenz K, Sekulla C, Schelle J, Schmeiss B, Brauckhoff M, Dralle H; German Neuromonitoring Study Group. What are normal quantitative parameters of intraoperative neuromonitoring (IONM) in thyroid surgery?. Langenbecks Arch Surg. 2010;395(7):901–9. 10. Randolph GW, Dralle H; International Intraoperative Monitoring Study Group. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope. 2011;121 Suppl 1:S1–S16.

Tiroid cerrahisinde aralıklı intraoperatif nöromonitorizasyonun elektromiyografik özellikleri

Year 2020, Volume: 8 Issue: 2, 131 - 137, 23.08.2020
https://doi.org/10.37696/nkmj.719020

Abstract

Amaç: Bu çalışmanın amacı aralıklı intraoperatif sinir monitorizasyonunun(I-IONM) püf noktalarını özetlemek ve anatomik uzunlukları birbirinden farklı olan sol ve sağ rekürren laringeal sinirin (RLN) elektrofizyolojik özelliklerini belirlemektir.
Materyal Method: Haziran 2016-Haziran 2017 tarihleri ​​arasında I-IONM kullanan 34 tiroidektomili hasta (27'i total tiroidektomili, 7'i hemitiroidektomili ) retrospektif olarak incelendi. Predisseksiyon (R1, V1) ve post-disseksiyon (R2, V2) sağ ve sol tarafın vagal siniri (VN) ve RLN'nin EMG dalga formları değerlendirildi.
Bulgular: Yaş ortalaması 43.85 ± 13.86 olan 29 kadın ve 5 erkek hasta vardı. 61 sinir I-IONM ile başarıyla değerlendirildi. Sağ RLN'nin ortalama R1 ve R2 genlikleri 280 ± 10 µV ve 270 ± 9µV idi; sol RLN sırasıyla 270 ± 10 µV ve 260 ± 9 µV idi. Sağ VN'nin ortalama V1 ve V2 genlikleri 210 ± 7µV ve 190 ± 7µV idi; sol VN sırasıyla 190 ± 5.4µV ve 170 ± 5µV idi. Sağ RLN'nin ortalama R1 ve R2 gecikmeleri 2.03 ± 0.42mS ve 2.0 ± 0.46mS; sol RLN sırasıyla 1.90 ± 0.30mS ve 1.96 ± 0.33mS idi. Sağ VN'nin ortalama V1 ve V2 latensleri 1.91 ± 0.46mS ve 1.82 ± 0.52mS idi; sol VN sırasıyla 2.01 ± 0.34mS ve 2.07 ± 0.38mS idi. VN ve RLN'nin EMG dalga formları açısından taraflar arasında istatistiksel olarak anlamlı bir fark yoktu.
Sonuç: Sol RLN'nin sağ RLN'den daha uzun anatomik uzunluğu vardır, ancak sinirin uzunluğunun genlik ve gecikmeyi etkilemediği sonucuna vardık.

References

  • 1. Calò PG, Pisano G, Medas F, Pittau MR, Gordini L, Demontis R, et al. Identification alone versus intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery: experience of 2034 consecutive patients. J Otolaryngol Head Neck Surg. 2014;43(1):16. 2. Sun H, Tian W, Jiang K, Chiang F, Wang P, Huang T, et al. Clinical guidelines on intraoperative neuromonitoring during thyroid and parathyroid surgery. Ann Transl Med. 2015;3(15):213. 3. Flisberg K, Lindholm T. Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol Suppl. 1969;263:63–7. 4. Caruso E, Pino A, Dionigi G, Pontin A. Safety of intraoperative neuromonitoring. Ann Thyroid. 2019;4:6. 5. Deniwar A, Kandil E, Randolph G. Electrophysiological neural monitoring of the laryngeal nerves in thyroid surgery: review of the current literature. Gland Surg. 2015;4(5):368–75. 6. Dralle H, Sekulla C, Lorenz K, Brauckhoff M, Machens A; German IONM Study Group. Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery. World J Surg. 2008;32(7):1358–66. 7. Chiang FY, Lee KW, Chen HC, Chen HY, Lu IC, Kuo WR, et al. Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World J Surg. 2010;34(2):223–9. 8. Mermelstein M, Von Weiler R, Rubinstein E. Intraoperative identification of laryngeal nerves with laryngeal electromyography. Laryngoscope. 1996;106:752–6. 9. Lorenz K, Sekulla C, Schelle J, Schmeiss B, Brauckhoff M, Dralle H; German Neuromonitoring Study Group. What are normal quantitative parameters of intraoperative neuromonitoring (IONM) in thyroid surgery?. Langenbecks Arch Surg. 2010;395(7):901–9. 10. Randolph GW, Dralle H; International Intraoperative Monitoring Study Group. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope. 2011;121 Suppl 1:S1–S16.
There are 1 citations in total.

Details

Primary Language English
Subjects Clinical Sciences
Journal Section Orginal Article
Authors

Serdar Gümüş 0000-0001-7629-9369

Edip Yılmaz 0000-0003-4318-9619

Yusuf Yağmur This is me 0000-0002-1466-4583

Publication Date August 23, 2020
Published in Issue Year 2020 Volume: 8 Issue: 2

Cite

APA Gümüş, S., Yılmaz, E., & Yağmur, Y. (2020). Electromyographic features of intermittent intraoperative neuromonitorization in the thyroid surgery. Namık Kemal Tıp Dergisi, 8(2), 131-137. https://doi.org/10.37696/nkmj.719020
AMA Gümüş S, Yılmaz E, Yağmur Y. Electromyographic features of intermittent intraoperative neuromonitorization in the thyroid surgery. NKMJ. August 2020;8(2):131-137. doi:10.37696/nkmj.719020
Chicago Gümüş, Serdar, Edip Yılmaz, and Yusuf Yağmur. “Electromyographic Features of Intermittent Intraoperative Neuromonitorization in the Thyroid Surgery”. Namık Kemal Tıp Dergisi 8, no. 2 (August 2020): 131-37. https://doi.org/10.37696/nkmj.719020.
EndNote Gümüş S, Yılmaz E, Yağmur Y (August 1, 2020) Electromyographic features of intermittent intraoperative neuromonitorization in the thyroid surgery. Namık Kemal Tıp Dergisi 8 2 131–137.
IEEE S. Gümüş, E. Yılmaz, and Y. Yağmur, “Electromyographic features of intermittent intraoperative neuromonitorization in the thyroid surgery”, NKMJ, vol. 8, no. 2, pp. 131–137, 2020, doi: 10.37696/nkmj.719020.
ISNAD Gümüş, Serdar et al. “Electromyographic Features of Intermittent Intraoperative Neuromonitorization in the Thyroid Surgery”. Namık Kemal Tıp Dergisi 8/2 (August 2020), 131-137. https://doi.org/10.37696/nkmj.719020.
JAMA Gümüş S, Yılmaz E, Yağmur Y. Electromyographic features of intermittent intraoperative neuromonitorization in the thyroid surgery. NKMJ. 2020;8:131–137.
MLA Gümüş, Serdar et al. “Electromyographic Features of Intermittent Intraoperative Neuromonitorization in the Thyroid Surgery”. Namık Kemal Tıp Dergisi, vol. 8, no. 2, 2020, pp. 131-7, doi:10.37696/nkmj.719020.
Vancouver Gümüş S, Yılmaz E, Yağmur Y. Electromyographic features of intermittent intraoperative neuromonitorization in the thyroid surgery. NKMJ. 2020;8(2):131-7.