Research Article
BibTex RIS Cite

Transcatheter Closure of Patent Ductus Arteriosus in infants between 2-10 kg

Year 2023, Volume: 17 Issue: 1, 30 - 38, 30.01.2023
https://doi.org/10.12956/tchd.1190725

Abstract

Objective: The aim of this study was to present our experiences on transcatheter patent ductus arteriosus (PDA) closure with different devices, mostly the Amplatzer Piccolo Occluder, in infants weighing between 2-10 kg.


Material and Methods
: In this study, the files of 31 patients who underwent transcatheter PDA closure between December 2019 and August 2022 were reviewed retrospectively.

Results: Transcatheter PDA closure was performed on 31(14 female) infants weighing between 2-10 kg. The mean age of patients was 10.7±6.7 months (2-28), and the mean weight was 6.6±2 kg (3-9.9). The median narrowest diameter of the ductus was 2.2 mm (IQR 2-3) and the median ductus length was 6 mm (IQR 4.75-8). The procedural success rate of all interventional procedures was 88% (30 of 34). Complications occurred in a total of four patients including failure of device implantation in one patient, post-procedural device embolization in 2 patients, and the significant residual shunt in one patient. None of the patients required surgery. In 34 interventional procedures, 3 of which were reintervention, 34 devices were used. Twenty-seven (79%) of them were Amplatzer Piccolo Occluder. The median fluoroscopy and procedural times were 10.5 minutes (IQR 7.25-18.5) and 40 minutes (IQR 35-57.5) respectively. The mean duration of follow-up was 10.3±8.8 months (1-32 months).


Conclusion:
In our experience, transcatheter treatment of PDA with the Amplatzer Piccolo Occluder device which was our first choice for appropriate duct anatomy and size in infants weighing between 2-10 kg, is safe and effective.

References

  • Latson LA, Hofschire PJ, Kugler JD, Cheatham JP, Gumbiner CH, Danford DA. Transcatheter closure of patent ductus arteriosus in pediatric patients. J Pediatr 1989;115:549-53.
  • Sathanandam SK, Gutfinger D, O’Brien L, Forbes T J, Gillespie MJ, Berman DP, et al. Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients ≥700 grams. Catheter Cardiovasc Interv 2020;96:1266-76
  • Bhat YA, Almesned A, Alqwaee A, Al Akhfash A. Catheter Closure of Clinically Silent Patent Ductus Arteriosus Using the Amplatzer Duct Occluder II-Additional Size: A Single-Center Experience. Cureus 2021;13:e17481.
  • Santoro G, Giordano M, Gaio G, Palladino MT, Capozzi G, Iacono C et al. Transcatheter Closure of Arterial Duct in Infants < 6 kg: Amplatzer Duct Occluder Type I vs Amplatzer Duct Occluder II Additional Sizes. Pediatr Cardiol 2018;39:627-32.
  • Barcroft M, McKee C, Berman DP, Taylor RA, Rivera BK, Smith CV et al. Percutaneous Closure of Patent Ductus Arteriosus. Clin Perinatol 2022;49:149-66.
  • Morville P, Akhavi A. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS. Catheter Cardiovasc Interv 2017;90:612-7.
  • Pamukcu O, Tuncay A, Narin N, Baykan A, Korkmaz L, Argun M et al. Patent Ductus Arteriosus closure in preterms less than 2kg: Surgery versus transcatheter. Int J Cardiol 2018;250:110-15.
  • Baspinar O, Sahin DA, Sulu A, Irdem A, Gokaslan G, Sivasli E, et al. Transcatheter closure of patent ductus arteriosus in under 6 kg and premature infants. J Interv Cardiol 2015;28:180-9.
  • O’Byrne ML, Millenson ME, Grady CB, Huang J, Bamat NA, Munson DA et al. Trends in transcatheter and operative closure of patent ductus arteriosus in neonatal intensive care units: Analysis of data from the Pediatric Health Information Systems Database. Am Heart J 2019;217:121-30.
  • Mahmoud HT, Santoro G, Gaio G, D’Aiello FA, Capogrosso C, Palladino MT, et al. Single-center experience in percutaneous closure of arterial duct with Amplatzer duct Occluder II additional sizes. Catheter Cardiovasc Interv 2017;89:1045-50.
  • Malekzadeh-Milani S, Akhavi A, Douchin S, Dauphin C, Chalard A, Mauran P, et al. Percutaneous closure of patent ductus arteriosus in premature infants: A French national survey. Catheter Cardiovasc Interv 2020;95:71-7.
  • Rodríguez Ogando A, Planelles Asensio I, de la Blanca ARS, Ballesteros Tejerizo F, Sánchez Luna M, Gil Jaurena JM, et al. Surgical Ligation Versus Percutaneous Closure of Patent Ductus Arteriosus in Very Low-Weight Preterm Infants: Which are the Real Benefits of the Percutaneous Approach?. Pediatr Cardiol 2018;39:398-410.
  • Pepeta L, Greyling A, Nxele MF, Makrexeni Z, Jiyana S. Ductal closure in infants under 6 kg including premature infants using AmplatzerTM duct occluder type two additional sizes: a single-centre experience in South Africa. Cardiovasc J Afr 2020;31:33-9.
  • Regan W, Benbrik N, Sharma SR, Auriau J, Bouvaist H, Bautista-Rodriguez C, et al. Improved ventilation in premature babies after transcatheter versus surgical closure of patent ductus arteriosus. Int J Cardiol 2020;311:22-7.
  • Drighil A, Al Jufan M, Al Omrane K, Al Atta J, Al Omrani A, Al Fadley F. Safety of transcatheter patent ductus arteriosus closure in small weight infants. J Interv Cardiol 2012;25:391-394.
  • Saliba Z, El-Rassi I, Helou D, Chehab G, Abdel-Massih T, Daou L, et al. Analyzing the failures of percutaneous closure of the patent ductus arteriosus in patients over 5 kg. J Invasive Cardiol 2012;24:434-8.
  • Philip R, Rush Waller B, Agrawal V, Wright D, Arevalo A, Zurakowski D, et al. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Catheter Cardiovasc Interv 2016;87:310-7.
  • Krichenko A, Benson LN, Burrows P, Möes CA, Laughlin P, Freedom RM. Angiographic classification of the isolated, CNY persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 1989;63:877–80.
  • Jux C. Piccolo devices in premie ductus arteriosi. Int J Cardiol 2020;311:37-8.
  • Park YA, Kim NK, Park SJ, Yun BS, Choi JY, Sul JH. Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less. Korean J Pediatr 2010;53:1012-7.
  • Backes CH, Rivera BK, Bridge JA, Armstrong AK, Boe BA, Berman DP, et al. Percutaneous Patent Ductus Arteriosus (PDA) Closure During Infancy: A Meta-analysis. Pediatrics 2017;139:e20162927.
  • Méot M, Haddad RN, Patkai J, Abu Zahira I, Di Marzio A, Szezepanski I et al. Spontaneous Closure of the Arterial Duct after Transcatheter Closure Attempt in Preterm Infants. Children (Basel) 2021;8:1138.
  • Baspinar O, Irdem A, Sivasli E, Sahin DA, Kilinc M. Comparison of the efficacy of different-sized Amplatzer duct occluders (I, II, and II AS) in children weighing less than 10 kg. Pediatr Cardiol 2013;34:88-94.
  • Eilers L, Qureshi AM. Advances in Pediatric Ductal Intervention: an Open or Shut Case?. Curr Cardiol Rep 2020;22:14.
  • Tanidir IC, Baspinar O, Saygi M, Kervancioglu M, Guzeltas A, Odemis E. Use of Lifetech™ Konar-MF, a device for both perimembranous and muscular ventricular septal defects: A multicentre study. Int J Cardiol 2020;310:43-50.

Patent Duktus Arteriyozus 'un Transkateter Kapatılması; 2-10 kg arası bebeklerde

Year 2023, Volume: 17 Issue: 1, 30 - 38, 30.01.2023
https://doi.org/10.12956/tchd.1190725

Abstract

Amaç: Bu çalışmanın amacı, 2-10 kg arası bebeklerde çoğunlukla Amplatzer Piccolo Occluder olmak üzere farklı cihazlarla transkateter patent duktus arteriyozus (PDA) kapatma konusundaki deneyimlerimizi sunmaktır.

Gereç ve Yöntemler: Bu çalışmada Aralık 2019-Ağustos 2022 tarihleri arasında transkateter PDA kapatılan 31 hastanın dosyaları geriye dönük olarak incelendi.

Bulgular: Toplam 31(14 kadın), 2-10 kg ağırlığındaki, bebeğe transkateter PDA kapaması yapıldı. Hastaların yaş ortalaması 10.7±6.7 ay (2-28) ve ortalama ağırlık 6.6±2 kg (3-9.9)’du. Duktusun en dar ortanca çapı 2.2 mm (IQR 2-3) ve ortanca duktus uzunluğu 6 mm (IQR 4.75-8)’di. Tüm girişimsel prosedürlerin prosedürel başarı oranı %88’di (30/34). Bir hastada cihaz implantasyonu başarısızlığı, 2 hastada işlem sonrası cihaz embolizasyonu ve bir hastada önemli rezidüel şant olmak üzere toplam dört hastada komplikasyon meydana geldi. Hiçbir hastada ameliyat gerekmedi. Üçü yeniden müdahale olmak üzere 34 girişimsel işlemde 34 cihaz kullanıldı. Bunların 27’si (%79) Amplatzer Piccolo Occluder’dı. Ortanca floroskopi ve prosedür süreleri sırasıyla 10.5 dakika (IQR 7.25-18.5) ve 40 dakika (IQR 35-57.5)’dı. Hastaların ortalama takip süresi 10.3±8.8 ay (1-32 ay)’dı.

Sonuç: Deneyimlerimize göre 2-10 kg arası bebeklerde uygun duktus anatomisi ve boyutu için ilk tercihimiz olan Amplatzer Piccolo Occluder cihazı ile PDA’nın transkateter tedavisi güvenli ve etkilidir.

References

  • Latson LA, Hofschire PJ, Kugler JD, Cheatham JP, Gumbiner CH, Danford DA. Transcatheter closure of patent ductus arteriosus in pediatric patients. J Pediatr 1989;115:549-53.
  • Sathanandam SK, Gutfinger D, O’Brien L, Forbes T J, Gillespie MJ, Berman DP, et al. Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients ≥700 grams. Catheter Cardiovasc Interv 2020;96:1266-76
  • Bhat YA, Almesned A, Alqwaee A, Al Akhfash A. Catheter Closure of Clinically Silent Patent Ductus Arteriosus Using the Amplatzer Duct Occluder II-Additional Size: A Single-Center Experience. Cureus 2021;13:e17481.
  • Santoro G, Giordano M, Gaio G, Palladino MT, Capozzi G, Iacono C et al. Transcatheter Closure of Arterial Duct in Infants < 6 kg: Amplatzer Duct Occluder Type I vs Amplatzer Duct Occluder II Additional Sizes. Pediatr Cardiol 2018;39:627-32.
  • Barcroft M, McKee C, Berman DP, Taylor RA, Rivera BK, Smith CV et al. Percutaneous Closure of Patent Ductus Arteriosus. Clin Perinatol 2022;49:149-66.
  • Morville P, Akhavi A. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS. Catheter Cardiovasc Interv 2017;90:612-7.
  • Pamukcu O, Tuncay A, Narin N, Baykan A, Korkmaz L, Argun M et al. Patent Ductus Arteriosus closure in preterms less than 2kg: Surgery versus transcatheter. Int J Cardiol 2018;250:110-15.
  • Baspinar O, Sahin DA, Sulu A, Irdem A, Gokaslan G, Sivasli E, et al. Transcatheter closure of patent ductus arteriosus in under 6 kg and premature infants. J Interv Cardiol 2015;28:180-9.
  • O’Byrne ML, Millenson ME, Grady CB, Huang J, Bamat NA, Munson DA et al. Trends in transcatheter and operative closure of patent ductus arteriosus in neonatal intensive care units: Analysis of data from the Pediatric Health Information Systems Database. Am Heart J 2019;217:121-30.
  • Mahmoud HT, Santoro G, Gaio G, D’Aiello FA, Capogrosso C, Palladino MT, et al. Single-center experience in percutaneous closure of arterial duct with Amplatzer duct Occluder II additional sizes. Catheter Cardiovasc Interv 2017;89:1045-50.
  • Malekzadeh-Milani S, Akhavi A, Douchin S, Dauphin C, Chalard A, Mauran P, et al. Percutaneous closure of patent ductus arteriosus in premature infants: A French national survey. Catheter Cardiovasc Interv 2020;95:71-7.
  • Rodríguez Ogando A, Planelles Asensio I, de la Blanca ARS, Ballesteros Tejerizo F, Sánchez Luna M, Gil Jaurena JM, et al. Surgical Ligation Versus Percutaneous Closure of Patent Ductus Arteriosus in Very Low-Weight Preterm Infants: Which are the Real Benefits of the Percutaneous Approach?. Pediatr Cardiol 2018;39:398-410.
  • Pepeta L, Greyling A, Nxele MF, Makrexeni Z, Jiyana S. Ductal closure in infants under 6 kg including premature infants using AmplatzerTM duct occluder type two additional sizes: a single-centre experience in South Africa. Cardiovasc J Afr 2020;31:33-9.
  • Regan W, Benbrik N, Sharma SR, Auriau J, Bouvaist H, Bautista-Rodriguez C, et al. Improved ventilation in premature babies after transcatheter versus surgical closure of patent ductus arteriosus. Int J Cardiol 2020;311:22-7.
  • Drighil A, Al Jufan M, Al Omrane K, Al Atta J, Al Omrani A, Al Fadley F. Safety of transcatheter patent ductus arteriosus closure in small weight infants. J Interv Cardiol 2012;25:391-394.
  • Saliba Z, El-Rassi I, Helou D, Chehab G, Abdel-Massih T, Daou L, et al. Analyzing the failures of percutaneous closure of the patent ductus arteriosus in patients over 5 kg. J Invasive Cardiol 2012;24:434-8.
  • Philip R, Rush Waller B, Agrawal V, Wright D, Arevalo A, Zurakowski D, et al. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Catheter Cardiovasc Interv 2016;87:310-7.
  • Krichenko A, Benson LN, Burrows P, Möes CA, Laughlin P, Freedom RM. Angiographic classification of the isolated, CNY persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 1989;63:877–80.
  • Jux C. Piccolo devices in premie ductus arteriosi. Int J Cardiol 2020;311:37-8.
  • Park YA, Kim NK, Park SJ, Yun BS, Choi JY, Sul JH. Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less. Korean J Pediatr 2010;53:1012-7.
  • Backes CH, Rivera BK, Bridge JA, Armstrong AK, Boe BA, Berman DP, et al. Percutaneous Patent Ductus Arteriosus (PDA) Closure During Infancy: A Meta-analysis. Pediatrics 2017;139:e20162927.
  • Méot M, Haddad RN, Patkai J, Abu Zahira I, Di Marzio A, Szezepanski I et al. Spontaneous Closure of the Arterial Duct after Transcatheter Closure Attempt in Preterm Infants. Children (Basel) 2021;8:1138.
  • Baspinar O, Irdem A, Sivasli E, Sahin DA, Kilinc M. Comparison of the efficacy of different-sized Amplatzer duct occluders (I, II, and II AS) in children weighing less than 10 kg. Pediatr Cardiol 2013;34:88-94.
  • Eilers L, Qureshi AM. Advances in Pediatric Ductal Intervention: an Open or Shut Case?. Curr Cardiol Rep 2020;22:14.
  • Tanidir IC, Baspinar O, Saygi M, Kervancioglu M, Guzeltas A, Odemis E. Use of Lifetech™ Konar-MF, a device for both perimembranous and muscular ventricular septal defects: A multicentre study. Int J Cardiol 2020;310:43-50.
There are 25 citations in total.

Details

Primary Language English
Subjects ​Internal Diseases
Journal Section ORIGINAL ARTICLES
Authors

Ahmet Vedat Kavurt 0000-0002-9756-4616

Seçil Sayın 0000-0001-6581-6121

Bilal Özelce 0000-0002-9107-4894

Denizhan Bağrul 0000-0003-0375-1726

Alper Gürsu 0000-0002-0707-2678

İbrahim Ece 0000-0002-3657-2209

İbrahim İlker Çetin 0000-0001-9480-8278

Publication Date January 30, 2023
Submission Date October 17, 2022
Published in Issue Year 2023 Volume: 17 Issue: 1

Cite

Vancouver Kavurt AV, Sayın S, Özelce B, Bağrul D, Gürsu A, Ece İ, Çetin İİ. Transcatheter Closure of Patent Ductus Arteriosus in infants between 2-10 kg. Türkiye Çocuk Hast Derg. 2023;17(1):30-8.


The publication language of Turkish Journal of Pediatric Disease is English.


Manuscripts submitted to the Turkish Journal of Pediatric Disease will go through a double-blind peer-review process. Each submission will be reviewed by at least two external, independent peer reviewers who are experts in the field, in order to ensure an unbiased evaluation process. The editorial board will invite an external and independent editor to manage the evaluation processes of manuscripts submitted by editors or by the editorial board members of the journal. The Editor in Chief is the final authority in the decision-making process for all submissions. Articles accepted for publication in the Turkish Journal of Pediatrics are put in the order of publication, with at least 10 original articles in each issue, taking into account the acceptance dates. If the articles sent to the reviewers for evaluation are assessed as a senior for publication by the reviewers, the section editor and the editor considering all aspects (originality, high scientific quality and citation potential), it receives publication priority in addition to the articles assigned for the next issue.


The aim of the Turkish Journal of Pediatrics is to publish high-quality original research articles that will contribute to the international literature in the field of general pediatric health and diseases and its sub-branches. It also publishes editorial opinions, letters to the editor, reviews, case reports, book reviews, comments on previously published articles, meeting and conference proceedings, announcements, and biography. In addition to the field of child health and diseases, the journal also includes articles prepared in fields such as surgery, dentistry, public health, nutrition and dietetics, social services, human genetics, basic sciences, psychology, psychiatry, educational sciences, sociology and nursing, provided that they are related to this field. can be published.