BibTex RIS Cite

An Evaluation of Fuel Consumption and Emission for Double Glazed Windows That Have Optimum Air Layer

Year 2016, Volume: 21 Issue: 2, 133 - 144, 13.10.2016
https://doi.org/10.17482/uujfe.30811

Abstract

In this study, CO2and SO2emission reductions and fuel consumption were examined for double-glazed windows that have optimum air layer thickness compared to single glazed windows in different degree-days. CO2and SO2emissions reductions tests were performed according to the combustion equations. Coal, natural gas and fuel oil were used as fuel. Calculations were made for degree-days between 1000-6000. Life cycle cost analysis and degree-days method were used in the calculations.

References

  • Arıcı M. and Karabay H. (2010) Determination of optimum thickness of double-glazed windows for the climatic regions of Turkey, Energy and Buildings, 42, 1773-1778
  • Ayçam İ. (2006). Türkiye derece gün bölgelerinde ısıtma gerektiren dönem için alçak katlı konut binalarında uygun cam tiplerinin saptanmasına yönelik bir yöntem, Doktora Tezi, Gazi Üniversitesi Fen Bilimleri Enstitüsü, Mimarlık Anabilim Dalı, Ankara.
  • Bektaş, B. ve Aksoy, U.T. (2005) Soğuk İklimlerdeki Binalarda Pencere Sistemlerinin Enerji Performansı, Fırat Üniv. Fen ve Müh. Bil. Der., 17, 3, 499-508.
  • Çomaklı, K. and Yüksel, B. (2004) Environmental impact of thermal insulation thickness in buildings, Applied Thermal Engineering, 24,5-6,933-940.
  • Ekinci C. E. (2003), Yalıtım Teknikleri, İstanbul.
  • Karabay H. and Arıcı M. (2012) Multiple pane window applications in various climatic regions of Turkey, Energy and Buildings, 45, 67-71.
  • Keçebaş A., (2015) Determination of optimum insulation thickness in pipe for exergetic life cycle assessment, Energy Conversion and Management, 105, 826-835.
  • Kon O., Bulgurcu H., Yüksel B. (2013) Farklı amaçlarla kullanılan binalar için çift camlı pencerelerin optimum hava tabakası kalınlığı ve yakıt tüketimi, 19.Ulusal Isı Bilimi ve Tekniği Kongresi (ULIBTK’13) , 550-556, Samsun.
  • Ulaş A. (2010) Binalarda TS 825 hesap yöntemine göre ısı kaybı, yakıt tüketimi, karbondioksit emisyonu hesabı ve maliyet analizi, Gazi Üniversitesi Fen Bilimleri Enstitüsü, Yüksek Lisans Tezi, Makine Mühendisliği Anabilim Dalı, Ankara.
  • Yildiz A. and Ersöz M. A. (2016), The effect of wind speed on the economical optimum insulation thickness for HVAC duct applications, Renewable and Sustainable Energy Reviews, 55, 1289-1300

OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ

Year 2016, Volume: 21 Issue: 2, 133 - 144, 13.10.2016
https://doi.org/10.17482/uujfe.30811

Abstract

Çalışmada, farklı derece-günler için optimum hava tabakası kalınlığına sahip çift camlı pencerelerin tek camlı pencerelere göre yakıt tüketimi, CO2 ve SO2 emisyonu tasarrufu incelenmiştir. CO2 ve SO2 emisyonu tasarrufu incelemeleri yanma denklemlerine göre yapılmıştır. Yakıt olarak kömür, doğal gaz ve fuel-oil kullanılmıştır. 1000-6000 arasındaki derece-günler için hesaplamalar yapılmıştır. Hesaplamalarda ömür maliyet analizi ve derece-gün metodu kullanılmıştır.

References

  • Arıcı M. and Karabay H. (2010) Determination of optimum thickness of double-glazed windows for the climatic regions of Turkey, Energy and Buildings, 42, 1773-1778
  • Ayçam İ. (2006). Türkiye derece gün bölgelerinde ısıtma gerektiren dönem için alçak katlı konut binalarında uygun cam tiplerinin saptanmasına yönelik bir yöntem, Doktora Tezi, Gazi Üniversitesi Fen Bilimleri Enstitüsü, Mimarlık Anabilim Dalı, Ankara.
  • Bektaş, B. ve Aksoy, U.T. (2005) Soğuk İklimlerdeki Binalarda Pencere Sistemlerinin Enerji Performansı, Fırat Üniv. Fen ve Müh. Bil. Der., 17, 3, 499-508.
  • Çomaklı, K. and Yüksel, B. (2004) Environmental impact of thermal insulation thickness in buildings, Applied Thermal Engineering, 24,5-6,933-940.
  • Ekinci C. E. (2003), Yalıtım Teknikleri, İstanbul.
  • Karabay H. and Arıcı M. (2012) Multiple pane window applications in various climatic regions of Turkey, Energy and Buildings, 45, 67-71.
  • Keçebaş A., (2015) Determination of optimum insulation thickness in pipe for exergetic life cycle assessment, Energy Conversion and Management, 105, 826-835.
  • Kon O., Bulgurcu H., Yüksel B. (2013) Farklı amaçlarla kullanılan binalar için çift camlı pencerelerin optimum hava tabakası kalınlığı ve yakıt tüketimi, 19.Ulusal Isı Bilimi ve Tekniği Kongresi (ULIBTK’13) , 550-556, Samsun.
  • Ulaş A. (2010) Binalarda TS 825 hesap yöntemine göre ısı kaybı, yakıt tüketimi, karbondioksit emisyonu hesabı ve maliyet analizi, Gazi Üniversitesi Fen Bilimleri Enstitüsü, Yüksek Lisans Tezi, Makine Mühendisliği Anabilim Dalı, Ankara.
  • Yildiz A. and Ersöz M. A. (2016), The effect of wind speed on the economical optimum insulation thickness for HVAC duct applications, Renewable and Sustainable Energy Reviews, 55, 1289-1300
There are 10 citations in total.

Details

Journal Section Research Articles
Authors

Okan Kon

Publication Date October 13, 2016
Submission Date January 28, 2016
Published in Issue Year 2016 Volume: 21 Issue: 2

Cite

APA Kon, O. (2016). OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, 21(2), 133-144. https://doi.org/10.17482/uujfe.30811
AMA Kon O. OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ. UUJFE. November 2016;21(2):133-144. doi:10.17482/uujfe.30811
Chicago Kon, Okan. “OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ”. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi 21, no. 2 (November 2016): 133-44. https://doi.org/10.17482/uujfe.30811.
EndNote Kon O (November 1, 2016) OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi 21 2 133–144.
IEEE O. Kon, “OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ”, UUJFE, vol. 21, no. 2, pp. 133–144, 2016, doi: 10.17482/uujfe.30811.
ISNAD Kon, Okan. “OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ”. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi 21/2 (November 2016), 133-144. https://doi.org/10.17482/uujfe.30811.
JAMA Kon O. OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ. UUJFE. 2016;21:133–144.
MLA Kon, Okan. “OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ”. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, vol. 21, no. 2, 2016, pp. 133-44, doi:10.17482/uujfe.30811.
Vancouver Kon O. OPTİMUM HAVA TABAKASINA SAHİP ÇİFT CAMLI PENCERELERİN YAKIT TÜKETİMİ VE EMİSYON AÇISINDAN DEĞERLENDİRİLMESİ. UUJFE. 2016;21(2):133-44.

Announcements:

30.03.2021-Beginning with our April 2021 (26/1) issue, in accordance with the new criteria of TR-Dizin, the Declaration of Conflict of Interest and the Declaration of Author Contribution forms fulfilled and signed by all authors are required as well as the Copyright form during the initial submission of the manuscript. Furthermore two new sections, i.e. ‘Conflict of Interest’ and ‘Author Contribution’, should be added to the manuscript. Links of those forms that should be submitted with the initial manuscript can be found in our 'Author Guidelines' and 'Submission Procedure' pages. The manuscript template is also updated. For articles reviewed and accepted for publication in our 2021 and ongoing issues and for articles currently under review process, those forms should also be fulfilled, signed and uploaded to the system by authors.