In this study, optimization of thermal insulation thickness applied to the external walls of buildings has been carried out comparatively based on the seasonal (space-heating and cooling) and the annual energy requirements considering solar radiation effect. This study has been performed for four degree-day regions of Turkey, namely, Iskenderun (in the first region), Istanbul (in the second region), Ankara (in the third region) and Ardahan (in the fourth region). By determining the sol-air temperatures for each region and maximizing the present worth value of seasonal and annual energy savings, the optimum thermal insulation thicknesses have been calculated. The effects of solar radiation on heating-cooling energy requirements, the variation of optimum insulation thicknesses and payback periods with respect to degree-day regions, the differences between the analyses based on seasonal and annual have been presented in tabular and graphical form.
Bu çalışmada dış duvarlara uygulanan yalıtım kalınlığının optimizasyonu, güneş radyasyonu etkisiyle birlikte hacimsel ısıtma, soğutma ve yıllık enerji gereksinimleri dikkate alınarak yapılmıştır. Bu çalışma, Türkiye’deki 4 derece-gün bölgesinde yer alan iller için yürütülmüştür: İskenderun (1. bölgede), İstanbul (2. bölgede), Ankara (3. bölgede) ve Ardahan (4. bölgede). Her bölge için güneş-hava sıcaklıkları belirlenerek sezonluk ve yıllık enerji tasarrufunu maksimize ederek optimum yalıtım kalınlıkları hesaplanmıştır. Güneş radyasyonunun ısıtma-soğutma enerji yüklerine etkisi, derece-gün bölgelerine göre optimum yalıtım kalınlıklarının ve geri ödeme sürelerinin değişimi, sezonluk ve yıllık analizler arasındaki farklar tablolar ve şekiller yardımıyla sunulmuştur.
Primary Language | English |
---|---|
Journal Section | Research Articles |
Authors | |
Publication Date | June 17, 2016 |
Submission Date | April 5, 2016 |
Published in Issue | Year 2016 Volume: 21 Issue: 1 |
Announcements:
30.03.2021-Beginning with our April 2021 (26/1) issue, in accordance with the new criteria of TR-Dizin, the Declaration of Conflict of Interest and the Declaration of Author Contribution forms fulfilled and signed by all authors are required as well as the Copyright form during the initial submission of the manuscript. Furthermore two new sections, i.e. ‘Conflict of Interest’ and ‘Author Contribution’, should be added to the manuscript. Links of those forms that should be submitted with the initial manuscript can be found in our 'Author Guidelines' and 'Submission Procedure' pages. The manuscript template is also updated. For articles reviewed and accepted for publication in our 2021 and ongoing issues and for articles currently under review process, those forms should also be fulfilled, signed and uploaded to the system by authors.