Olgu Sunumu
BibTex RIS Kaynak Göster
Yıl 2019, Cilt: 1 Sayı: 2, 104 - 108, 30.08.2019

Öz

Kaynakça

  • 1. Alvi A, Doherty T, Lewen G. Facial fractures and concomitant injuries in trauma patients. Laryngoscope. 2003 Jan;113(1):102-6
  • 2. Gabrielli MF, Monnazzi MS, Passeri LA, Carvalho WR, Gabrielli M, Hochuli-Vieira E. Orbital wall reconstruction with titanium mesh: retrospective study of 24 patients. Craniomaxillofac Trauma Reconstr. 2011 Sep;4(3):151-6
  • 3. Turvey TA, Golden BA. Orbital anatomy for the surgeon. Oral Maxillofac Surg Clin North Am. 2012 Nov;24(4):525-36
  • 4. Buchanan EP, Hopper RA, Suver DW, Hayes AG, Gruss JS, Birgfeld CB. Zygomaticomaxillary complex fractures and their association with naso-orbito-ethmoid fractures: a 5-year review. Plast Reconstr Surg. 2012 Dec;130(6):1296-304
  • 5. Grob S, Yonkers M, Tao J. Orbital fracture Repair. Seminars in Plastic Surger. 2017 Feb; 31(1): 31–9
  • 6. Yaremchuk MJ, Del Vecchio DA, Fiala TG, Lee WP. Microfixation of acute orbital fractures. Ann Plast Surg. 1993 May;30(5):385-97
  • 7. Gruss JS, Van Wyck L, Phillips JH, Antonyshyn O. The importance of the zygomatic arch in complex midfacial fracture repair and correction of posttraumatic orbitozygomatic deformities. Plast Reconstr Surg. 1990 Jun;85(6):878-90
  • 8. Schreurs R, Dubois L, Becking AG, Maal TJJ. The orbit first! A novel surgical treatment protocol for secondary orbitozygomatic reconstruction. J Craniomaxillofac Surg. 2017 Jul;45(7):1043-50
  • 9. Cho J, Ryu J. Alternative Treatment for Blow-In Fracture of Lateral Orbital Wall: Removal of the Fractured Fragment. J Craniofac Surg. 2016 Nov;27(8):2159-61
  • 10. Hollier LH, Thornton J, Pazmino P, Stal S. The management of orbitozygomatic fractures. Plast Reconstr Surg. 2003;111:2386–92.
  • 11. Mukherjee B, Priyadarshini O, Ramasubramanian S, Agarkar S. Iatrogenic Injury to Medial Rectus After Endoscopic Sinus Surgery. Indian Journal Otolaryngology Head Neck Surgery 2015 Dec;67(4):394-402
  • 12. Peter Cikatricis P, Salvi SM, Burke JP. Iatrogenic Lateral Rectus Transection Secondary to Dental Implantation Surgery, Orbit, (2008) 27:4, 305-7
  • 13. Del Moro G, Fabris S, Longatti P, Scarpa G. Watch the screw. An unusual complication of orbital reconstruction. J Oral Maxillofac Surg. 2014 Mar;72(3):645.e1-6
  • 14. Lee HB, Nunery WR. Orbital adherence syndrome secondary to titanium implant material. Ophthalmic Plast Reconstr Surg. 2009 Jan-Feb;25(1):33-6
  • 15. Shah HA, Shipchandler T, Vernon D, et al. Extra-ocular movement restriction and diplopia following orbital fracture repair. Am J Otolaryngol. 2018 Jan - Feb;39(1):34-6
  • 16. Hwang CJ, Katowitz WR, Volpe NJ. Orbital metallic mesh causing chronic intraocular foreign body and restrictive strabismus. Ophthalmic Plast Reconstr Surg. 2007 Jul-Aug;23(4):312-3
  • 17. Costa PJC, de Gauw JH, Costa Filho JZ, Moreira RT, Ribeiro Júnior PD. Late Complication Associated With the Treatment of Orbital Floor Fracture With Titanium Mesh. J Craniofac Surg. 2018 Sep;29(6):e623-4
  • 18. Koktekir BE, Bakbak B, Karamese M, Gedik S, Tosun Z. Scleral perforation complicating titanium mesh plaque in orbital blowout fracture. J Craniofac Surg. 2012 Jul;23(4):964-5
  • 19. Chandra V, Buck D, Chakrabarti R, McNab A. Orbital Plates and Screws Causing Globe Fixation: A Rare and Delayed Complication of Craniomaxillofacial Surgery. Ophthalmic Plast Reconstr Surg. 2018 May/Jun;34(3):e95-6
  • 20. Sadiq MA, Prabhu SP, Fearon JA, et al. Screw implantation in the globe: the risk of delayed hardware migration from craniofacial repair. J Craniofac Surg 2013;24:1650–2
  • 21. Islamoglu K, Coskunfirat OK, Tetik G, et al. Complications and removal rates of miniplates and screws used for maxillofacial fractures. Ann Plast Surg 2002;48:265-8
  • 22. Strominger MB. Incomitant esotropia secondary to lateral rectus injury. Am Orthopt J. 2004;54:135-8

Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair

Yıl 2019, Cilt: 1 Sayı: 2, 104 - 108, 30.08.2019

Öz

Purpose: In this case report, we present a patient with lateral rectus muscle injury caused by excessive long screws inserted into the orbital rim by the plastic and reconstructive surgery department.
Case Presentation: A 60 year-old male patient presented with diplopia, esotropia and enopthalmus in his right eye fallowing orbital inferior wall fracture and tripod fracture surgery due to maxillofacial trauma. In first examination limitation of right abduction was determined. Forced duction test showed that restriction in horizontal movements. Computed tomography showed the screws placed on the lateral wall were pushed into the orbit and pressed into the lateral rectus. After the removal of the screws, diplopia was improved but restriction of abduction still persistant.
Conclusion: During the drilling and placement of the screws attention should be paid to the protection of structures. Iatrogenic injuries of extra-ocular muscles should be considered if there is a restriction of eye movement after orbital fracture surgery.

Kaynakça

  • 1. Alvi A, Doherty T, Lewen G. Facial fractures and concomitant injuries in trauma patients. Laryngoscope. 2003 Jan;113(1):102-6
  • 2. Gabrielli MF, Monnazzi MS, Passeri LA, Carvalho WR, Gabrielli M, Hochuli-Vieira E. Orbital wall reconstruction with titanium mesh: retrospective study of 24 patients. Craniomaxillofac Trauma Reconstr. 2011 Sep;4(3):151-6
  • 3. Turvey TA, Golden BA. Orbital anatomy for the surgeon. Oral Maxillofac Surg Clin North Am. 2012 Nov;24(4):525-36
  • 4. Buchanan EP, Hopper RA, Suver DW, Hayes AG, Gruss JS, Birgfeld CB. Zygomaticomaxillary complex fractures and their association with naso-orbito-ethmoid fractures: a 5-year review. Plast Reconstr Surg. 2012 Dec;130(6):1296-304
  • 5. Grob S, Yonkers M, Tao J. Orbital fracture Repair. Seminars in Plastic Surger. 2017 Feb; 31(1): 31–9
  • 6. Yaremchuk MJ, Del Vecchio DA, Fiala TG, Lee WP. Microfixation of acute orbital fractures. Ann Plast Surg. 1993 May;30(5):385-97
  • 7. Gruss JS, Van Wyck L, Phillips JH, Antonyshyn O. The importance of the zygomatic arch in complex midfacial fracture repair and correction of posttraumatic orbitozygomatic deformities. Plast Reconstr Surg. 1990 Jun;85(6):878-90
  • 8. Schreurs R, Dubois L, Becking AG, Maal TJJ. The orbit first! A novel surgical treatment protocol for secondary orbitozygomatic reconstruction. J Craniomaxillofac Surg. 2017 Jul;45(7):1043-50
  • 9. Cho J, Ryu J. Alternative Treatment for Blow-In Fracture of Lateral Orbital Wall: Removal of the Fractured Fragment. J Craniofac Surg. 2016 Nov;27(8):2159-61
  • 10. Hollier LH, Thornton J, Pazmino P, Stal S. The management of orbitozygomatic fractures. Plast Reconstr Surg. 2003;111:2386–92.
  • 11. Mukherjee B, Priyadarshini O, Ramasubramanian S, Agarkar S. Iatrogenic Injury to Medial Rectus After Endoscopic Sinus Surgery. Indian Journal Otolaryngology Head Neck Surgery 2015 Dec;67(4):394-402
  • 12. Peter Cikatricis P, Salvi SM, Burke JP. Iatrogenic Lateral Rectus Transection Secondary to Dental Implantation Surgery, Orbit, (2008) 27:4, 305-7
  • 13. Del Moro G, Fabris S, Longatti P, Scarpa G. Watch the screw. An unusual complication of orbital reconstruction. J Oral Maxillofac Surg. 2014 Mar;72(3):645.e1-6
  • 14. Lee HB, Nunery WR. Orbital adherence syndrome secondary to titanium implant material. Ophthalmic Plast Reconstr Surg. 2009 Jan-Feb;25(1):33-6
  • 15. Shah HA, Shipchandler T, Vernon D, et al. Extra-ocular movement restriction and diplopia following orbital fracture repair. Am J Otolaryngol. 2018 Jan - Feb;39(1):34-6
  • 16. Hwang CJ, Katowitz WR, Volpe NJ. Orbital metallic mesh causing chronic intraocular foreign body and restrictive strabismus. Ophthalmic Plast Reconstr Surg. 2007 Jul-Aug;23(4):312-3
  • 17. Costa PJC, de Gauw JH, Costa Filho JZ, Moreira RT, Ribeiro Júnior PD. Late Complication Associated With the Treatment of Orbital Floor Fracture With Titanium Mesh. J Craniofac Surg. 2018 Sep;29(6):e623-4
  • 18. Koktekir BE, Bakbak B, Karamese M, Gedik S, Tosun Z. Scleral perforation complicating titanium mesh plaque in orbital blowout fracture. J Craniofac Surg. 2012 Jul;23(4):964-5
  • 19. Chandra V, Buck D, Chakrabarti R, McNab A. Orbital Plates and Screws Causing Globe Fixation: A Rare and Delayed Complication of Craniomaxillofacial Surgery. Ophthalmic Plast Reconstr Surg. 2018 May/Jun;34(3):e95-6
  • 20. Sadiq MA, Prabhu SP, Fearon JA, et al. Screw implantation in the globe: the risk of delayed hardware migration from craniofacial repair. J Craniofac Surg 2013;24:1650–2
  • 21. Islamoglu K, Coskunfirat OK, Tetik G, et al. Complications and removal rates of miniplates and screws used for maxillofacial fractures. Ann Plast Surg 2002;48:265-8
  • 22. Strominger MB. Incomitant esotropia secondary to lateral rectus injury. Am Orthopt J. 2004;54:135-8
Toplam 22 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Göz Hastalıkları
Bölüm Case Report
Yazarlar

Zeynep Zahide Güllülü

Osman Okan Olcaysü

Berna Akova Budak

Sertaç Argun Kıvanç

Yayımlanma Tarihi 30 Ağustos 2019
Kabul Tarihi 25 Aralık 2019
Yayımlandığı Sayı Yıl 2019 Cilt: 1 Sayı: 2

Kaynak Göster

APA Güllülü, Z. Z., Olcaysü, O. O., Akova Budak, B., Kıvanç, S. A. (2019). Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair. Clinical and Experimental Ocular Trauma and Infection, 1(2), 104-108.
AMA Güllülü ZZ, Olcaysü OO, Akova Budak B, Kıvanç SA. Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair. CEOTI. Ağustos 2019;1(2):104-108.
Chicago Güllülü, Zeynep Zahide, Osman Okan Olcaysü, Berna Akova Budak, ve Sertaç Argun Kıvanç. “Injury Of The Orbit With Screws Secondary To Lateral Orbital Wall Repair”. Clinical and Experimental Ocular Trauma and Infection 1, sy. 2 (Ağustos 2019): 104-8.
EndNote Güllülü ZZ, Olcaysü OO, Akova Budak B, Kıvanç SA (01 Ağustos 2019) Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair. Clinical and Experimental Ocular Trauma and Infection 1 2 104–108.
IEEE Z. Z. Güllülü, O. O. Olcaysü, B. Akova Budak, ve S. A. Kıvanç, “Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair”, CEOTI, c. 1, sy. 2, ss. 104–108, 2019.
ISNAD Güllülü, Zeynep Zahide vd. “Injury Of The Orbit With Screws Secondary To Lateral Orbital Wall Repair”. Clinical and Experimental Ocular Trauma and Infection 1/2 (Ağustos 2019), 104-108.
JAMA Güllülü ZZ, Olcaysü OO, Akova Budak B, Kıvanç SA. Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair. CEOTI. 2019;1:104–108.
MLA Güllülü, Zeynep Zahide vd. “Injury Of The Orbit With Screws Secondary To Lateral Orbital Wall Repair”. Clinical and Experimental Ocular Trauma and Infection, c. 1, sy. 2, 2019, ss. 104-8.
Vancouver Güllülü ZZ, Olcaysü OO, Akova Budak B, Kıvanç SA. Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair. CEOTI. 2019;1(2):104-8.