In this paper, the output voltage of the buck type DC voltage reducer
that is used for the aim of efficient energy transmission is controlled. The
discrete PI algorithm is chosen for the control process. The controller
parameters Kp and Ki in order to ensure the faultless pursuit of reference DC
output voltage level with output voltage of the converter lowest overflow
percentage and settling time is optimized. Ant Colony Algorithm that is one of
the iterative algorithms has been used in the optimization process.
Simultaneous studies have been realized and the results obtained are compared
and discussed with the results in the literature. Compared to the performance
criteria that are important for the controller, it is seen that the settling
time is shorter and the overshoot values are lower.
DC-DC converter Buck converter PI controller Ant colony optimization algorithm
Bu çalışmada, verimli enerji iletimi amacıyla kullanılan Buck tipi DC
gerilim seviye düşürücüsünün, çıkış büyüklüğü kontrol altına alınmıştır.
Kontrol süreci için ayrık zaman PI algoritması seçilmiştir. Kontrolöre ait Kp
ve Ki parametreleri dönüştürücünün çıkış büyüklüğünün en düşük aşım yüzdesi ve
yerleşme zamanı ile referans DC gerilim seviyesini hatasız takibini
sağlanabilmesi amacıyla optimize edilmiştir. Optimizasyon, iteratif bir
algoritma olan Karınca Kolonisi (ACO) algoritması ile sağlanmıştır. Kontrol
sürecine ait eşzamanlı çalışmalar Matlab-Simulink üzerinden gerçekleştirilmiş;
elde edilen sonuçlar literatürdeki sonuçlarla karşılaştırılıp tartışılmıştır. Kontrolör
için önemli olan performans kriterleri açısında yapılan karşılaştırmalara göre,
yerleşme zamanın daha kısa olduğu ve aşım değerlerinin daha düşük olduğu
görülmüştür.
DC-DC dönüştürücü buck converter PI kontrolcü Karınca koloni optimizasyon algoritması
Bölüm | Makaleler |
---|---|
Yazarlar | |
Yayımlanma Tarihi | 15 Aralık 2017 |
Yayımlandığı Sayı | Yıl 2017 Cilt: 32 Sayı: 4 |