Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2019, , 253 - 262, 30.12.2019
https://doi.org/10.36222/ejt.648601

Öz

Kaynakça

  • [1] Heperkan H.A., Bircan M.M., Sevindir M.K. (2001). Vapor diffusion and condensation in building materials, V. National Installation Engineering Congress and Exhibition, İzmir, TURKEY, 461-469
  • [2] Umaroğulları F., Zorer Gedik, G., Mıhlayanlar, E. (2011). Condensation Control of Insulated and Uninsulated Concrete Walls in the Periodic Regime: The Case of Edirne. megaronjournal, 6(1), 13-20
  • [3] Kavas, E., Thermal Protected Wall Sections in Eastern Anatolia Region and Condensation Control (Erzurum Case), Master Thesis, Yıldız Technical University, İstanbul, TURKEY, 1997
  • [4] Akman, S., Building damage and repair principles, TMMOB Publications, İstanbul, TURKEY, 2000
  • [5] Bircan, M.M., Computer program for the examination of the vapor diffusion process in building materials and condensation calculation, Mater Thesis, Yıldız Technical University, İstanbul, TURKEY,1999.
  • [6] Yüksek İ., Sıvacılar S.( 2017). Thermal Efficiency of Different Types Covered Walls TS 825 A Comparative Study on Conditions in Turkey. Politeknik Journal, 20 (2), 291-302
  • [7] Özel, M, İlgin Beyazıt, N . (2018). Condensation Analysis According to Different Location of Insulation in Wall. Dicle University Journal of Engineering Faculty(DÜMF), 9 (2), 785-794
  • [8] Glaser, H. (1959). Graphisches Verfahren zur Untersuchung von Diffusionsvorgangen, Kaltetechnik 11, Heft 10/59, 345-349
  • [9] Anon., DIN 4108, Warmeschutz im Hochbau, Beuth Verlag GmbH, Berlin, 1981
  • [10] Anon., TS 825 Thermal Insulation Rules in Buildings, Turkish Standard Draft, Ankara, 2008

CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE

Yıl 2019, , 253 - 262, 30.12.2019
https://doi.org/10.36222/ejt.648601

Öz

In
this study, condensation and vapor diffusion caused by different positioned
insulation in the wall for Mardin province were analyzed. In the analysis,
according to 2008 standard of TS 825, Glaser graphing method and graphical user
interface (GUI) were used in MATLAB. Extruded polyurethane foam was used as the
insulation material and normal unreinforced concrete was selected as the wall.
Evaporation and condensation amounts were determined by creating 6 different
wall models with the same insulation thickness of 20 cm thick and unreinforced
concrete wall covered with 2 cm plaster on the inside and 3 cm thickness on the
outside. The data obtained for 2 cm and 4 cm insulation thicknesses are
presented in tables and the results are interpreted for Mardin province. As a
result, it was seen that the worst wall structure in terms of condensation and
evaporation was obtained in the middle insulated wall and later in the interior
insulated wall structure. The externally insulated wall showed no condensation.

Kaynakça

  • [1] Heperkan H.A., Bircan M.M., Sevindir M.K. (2001). Vapor diffusion and condensation in building materials, V. National Installation Engineering Congress and Exhibition, İzmir, TURKEY, 461-469
  • [2] Umaroğulları F., Zorer Gedik, G., Mıhlayanlar, E. (2011). Condensation Control of Insulated and Uninsulated Concrete Walls in the Periodic Regime: The Case of Edirne. megaronjournal, 6(1), 13-20
  • [3] Kavas, E., Thermal Protected Wall Sections in Eastern Anatolia Region and Condensation Control (Erzurum Case), Master Thesis, Yıldız Technical University, İstanbul, TURKEY, 1997
  • [4] Akman, S., Building damage and repair principles, TMMOB Publications, İstanbul, TURKEY, 2000
  • [5] Bircan, M.M., Computer program for the examination of the vapor diffusion process in building materials and condensation calculation, Mater Thesis, Yıldız Technical University, İstanbul, TURKEY,1999.
  • [6] Yüksek İ., Sıvacılar S.( 2017). Thermal Efficiency of Different Types Covered Walls TS 825 A Comparative Study on Conditions in Turkey. Politeknik Journal, 20 (2), 291-302
  • [7] Özel, M, İlgin Beyazıt, N . (2018). Condensation Analysis According to Different Location of Insulation in Wall. Dicle University Journal of Engineering Faculty(DÜMF), 9 (2), 785-794
  • [8] Glaser, H. (1959). Graphisches Verfahren zur Untersuchung von Diffusionsvorgangen, Kaltetechnik 11, Heft 10/59, 345-349
  • [9] Anon., DIN 4108, Warmeschutz im Hochbau, Beuth Verlag GmbH, Berlin, 1981
  • [10] Anon., TS 825 Thermal Insulation Rules in Buildings, Turkish Standard Draft, Ankara, 2008
Toplam 10 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Makine Mühendisliği
Bölüm Araştırma Makalesi
Yazarlar

Fatih Ünal 0000-0001-6660-9984

Yayımlanma Tarihi 30 Aralık 2019
Yayımlandığı Sayı Yıl 2019

Kaynak Göster

APA Ünal, F. (2019). CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. European Journal of Technique (EJT), 9(2), 253-262. https://doi.org/10.36222/ejt.648601

All articles published by EJT are licensed under the Creative Commons Attribution 4.0 International License. This permits anyone to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited.Creative Commons Lisansı