Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2020, Cilt: 35 Sayı: 3, 1551 - 1564, 07.04.2020
https://doi.org/10.17341/gazimmfd.520680

Öz

Kaynakça

  • [1] Kazerooni H., Steger R. ve Huang L., “Hybrid control of the Berkeley lower extremity exoskeleton (BLEEX)”, The International Journal of Robotics Research, 25(5-6), 561-573, 2006.
  • [2] Neuhaus P.D., Noorden J.H., Craig T.J., Torres T., Kirschbaum J. ve Pratt J.E., “Design and evaluation of Mina: A robotic orthosis for paraplegics”, In Rehabilitation Robotics (ICORR), 2011 IEEE International Conference on (pp. 1-8), 2011.
  • [3] Suzuki K., Mito G., Kawamoto H., Hasegawa Y. ve Sankai Y., “Intention-based walking support for paraplegia patients with Robot Suit HAL”, Advanced Robotics, 21(12), 1441-1469, 2007.
  • [4] Veneman J.F., Kruidhof R., Hekman E.E., Ekkelenkamp R., Van Asseldonk E.H. ve Van Der Kooij H., “Design and evaluation of the LOPES exoskeleton robot for interactive gait rehabilitation”, IEEE Transactions on Neural Systems and Rehabilitation Engineering, 15(3), 379-386, 2007.
  • [5] Van Ham R., Sugar T.G., Vanderborght B., Hollander K.W. ve Lefeber D., “Compliant actuator designs”, IEEE Robotics & Automation Magazine, 16(3), 2009.
  • [6] Migliore S.A., Brown E.A. ve DeWeerth S.P., “Biologically inspired joint stiffness control”, In Robotics and Automation, Proceedings of the 2005 IEEE International Conference on (pp. 4508-4513), 2005.
  • [7] Wang S., Wang L., Meijneke C., Van Asseldonk E., Hoellinger T., Cheron G. ve Tamburella F., “Design and control of the MINDWALKER exoskeleton”, IEEE transactions on neural systems and rehabilitation engineering, 23(2), 277-286, 2015.
  • [8] Kwa H.K., Noorden J.H., Missel M., Craig T., Pratt J.E. ve Neuhaus P.D., “Development of the IHMC mobility assist exoskeleton”, In Robotics and Automation, IEEE International Conference on pp. 2556-2562, 2009.
  • [9] Pratt J.E., Krupp B.T., Morse C.J. ve Collins S.H., “The RoboKnee: an exoskeleton for enhancing strength and endurance during walking”, IEEE international conference on robotics and automation, proceedings, vol. 3, pp 2430–2435, 2004.
  • [10] Cestari M., Sanz-Merodio D., Arevalo J.C., ve Garcia E., “ARES, a variable stiffness actuator with embedded force sensor for the ATLAS exoskeleton”, Industrial Robot: An International Journal, 41(6), 518-526, 2014.
  • [11] Cestari M., Sanz-Merodio D., Arevalo J. C., ve Garcia E., “An adjustable compliant joint for lower-limb exoskeletons”, IEEE/ASME Transactions on Mechatronics, 20(2), 889-898, 2015.
  • [12] Zhu J., Wang Y., Jiang J., Sun B. ve Cao H., “Unidirectional variable stiffness hydraulic actuator for load-carrying knee exoskeleton”, International Journal of Advanced Robotic Systems, 14(1), 1729881416686955, 2017.
  • [13] Vanderborght B., Tsagarakis N. G., Semini C., Van Ham R. ve Caldwell D.G., “MACCEPA 2.0: Adjustable compliant actuator with stiffening characteristic for energy efficient hopping”, In Robotics and Automation, 2009. ICRA'09. IEEE International Conference on (pp. 544-549). IEEE, 2009.
  • [14] Jafari A., Tsagarakis N. G., Sardellitti I., ve Caldwell D.G., “A new actuator with adjustable stiffness based on a variable ratio lever mechanism”, IEEE/ASME Transactions on Mechatronics, 19(1), 55-63, 2014.
  • [15] Liu L., Leonhardt S. ve Misgel B.J., “Design and control of a mechanical rotary variable impedance actuator”, Mechatronics, 39, 226-236, 2016.
  • [16] Sun J., Zhang Y., Zhang C., Guo Z. ve Xiao X., “Mechanical design of a compact Serial Variable Stiffness Actuator (SVSA) based on lever mechanism”, In Robotics and Automation (ICRA), 2017 IEEE International Conference on (pp. 33-38). IEEE, 2017.
  • [17] Tsagarakis N.G., Sardellitti I., ve Caldwell D. G., “A new variable stiffness actuator (CompAct-VSA): Design and modelling”, In Intelligent Robots and Systems (IROS), 2011 IEEE/RSJ International Conference on (pp. 378-383). IEEE, 2011.
  • [18] Dežman M., ve Gams A. “Rotatable cam-based variable-ratio lever compliant actuator for wearable devices”, Mechanism and Machine Theory, 130, 508-522, 2018.
  • [19] Wolf S., ve Hirzinger G., “A new variable stiffness design: Matching requirements of the next robot generation”, In Robotics and Automation, IEEE International Conference on (pp. 1741-1746), 2008.
  • [20] Baser O. ve Kizilhan H., “Mechanical design and preliminary tests of VS-AnkleExo”, Journal of the Brazilian Society of Mechanical Sciences and Engineering, 40(442), 1-16, 2018.
  • [21] Sun J., Guo Z., Sun D., He S., ve Xiao X., “Design, modeling and control of a novel compact, energy-efficient, and rotational serial variable stiffness actuator (SVSA-II)”, Mechanism and Machine Theory, 130, 123-136, 2018.
  • [22] Schiavi R., Grioli G., Sen S. ve Bicchi A., “VSA-II: A novel prototype of variable stiffness actuator for safe and performing robots interacting with humans”, In Robotics and Automation, 2008, IEEE International Conference on (pp. 2171-2176), 2008.
  • [23] Kim B.S. ve Song J.B., “Design and Control of a Variable Stiffness Actuator Based on Adjustable Moment Arm”, IEEE Trans. Robotics, 28(5), 1145-1151, 2012.
  • [24] Zhang C., Liu G., Li C., Zhao J., Yu H. ve Zhu Y., “Development of a lower limb rehabilitation exoskeleton based on real-time gait detection and gait tracking”, Advances in Mechanical Engineering, 8(1), 1687814015627982, 2016.
  • [25] Madani T., Daachi B. ve Djouani K., “Non-singular terminal sliding mode controller: Application to an actuated exoskeleton”, Mechatronics, 33, 136-145, 2016.
  • [26] Cao F., Li C. ve Li Y., “Robust sliding mode adaptive control for lower extremity exoskeleton”, In Chinese Automation Congress (CAC), 2015 (pp. 400-405), 2015.
  • [27] Guo Z., Pan Y., Sun T., Zhang Y. ve Xiao X., “Adaptive neural network control of serial variable stiffness actuators”, Complexity, 2017.
  • [28] Shi P., Lei C., Zhang Y., Wang Y. ve Wang F., “PID control of the mechanical legs based on fuzzy adaptive”, In Cyber Technology in Automation, Control, and Intelligent Systems (CYBER), 2015 IEEE International Conference on (pp. 1965-1970), 2015.
  • [29] Khosla A., Leena G. ve Soni M.K., “Performance evaluation of various control techniques for inverted pendulum”, Performance Evaluation, 3(4), 1096-1102, 2013.
  • [30] Shamaei K., Sawicki G.S. ve Dollar A.M., “Estimation of quasi-stiffness and propulsive work of the human ankle in the stance phase of walking”, PloS one 2013, 8(3), e59935, 2013.
  • [31] Kizilhan H., Baser O., Kilic E. ve Ulusoy N., “Comparison of controllable transmission ratio type variable stiffness actuator with antagonistic and pre-tension type actuators for the joints exoskeleton robots”, In 12th international conference on informatics in control, automation and robotics (ICINCO), vol. 2, pp 188–195, 2015.
  • [32] Pan D., Gao F., Miao Y. ve Cao R., “Co-simulation research of a novel exoskeleton-human robot system on humanoid gaits with fuzzy-PID/PID algorithms”, Advances in Engineering Software, 79, 36-46, 2015.
  • [33] Bovi G., Rabuffetti M., Mazzoleni P. and Ferrarin M., “A multiple-task gait analysis approach: kinematic, kinetic and EMG reference data for healthy young and adult subjects”, Gait & posture, 33(1), 6-13, 2011.

Sertliği değiştirilebilir bir ayak bileği dış iskelet robotun çeşitli kontrolcüler ile pozisyon takibi kontrol performansının değerlendirilmesi

Yıl 2020, Cilt: 35 Sayı: 3, 1551 - 1564, 07.04.2020
https://doi.org/10.17341/gazimmfd.520680

Öz

İnsan alt uzuv eklemleri biyomekaniği literatür
çalışmalarına göre ayak bileği kas-iskelet sistemi yürüme esnasında sürekli
olarak eklem sertliğini değiştirmektedir. İnsan bileği ekleminin bu biyomekanik
davranışından esinlenilerek, VS-AnkleExo (Variable Stiffness Ankle Exoskeleton)
isimli değişken sertliğe sahip bir eyleyici ile tahrik edilen ayak bileği dış
iskelet robot tasarımı ortaya koyulmuştur. Sertliği değiştirilebilir bir bilek
eklemi tasarımı ile esnek, güvenli ve biyomimetik bir hareket kabiliyeti
sağlamasına karşın dış etkiler altında kararlı ve hassas pozisyon takibinin
zorluğu bu tür yumuşak eyleyicilerin en büyük problemidir. Bu makalede,
VS-AnkleExo üzerinde geleneksel Oransal İntegral Türev (Proportional Derivative
Integral – PID ) kontrol yönteminin ve bulanık mantık teorisinin farklı
tiplerde kombine edilmesi ile oluşturulan karma kontrolcülerin pozisyon takip
performansı ve dış bozuculara karşı duyarlılı
kları deneysel olarak değerlendirilmiştir.
VS-AnkleExo rehabilitasyon ve yürüme yardımı gibi uygulamalar için
kullanılacaktır. Bu uygulamalarda ise genellikle pozisyon takibine dayanan
tekrarlı hareket egzersizleri kullanılmaktadır. Bu kapsamda, çalışmada ilk
olarak bozucu etkiler olmadan farklı referanslar için geleneksel PID, Bulanık
PD, Bulanık PD+I, Bulanık PD+PID ve ZTS (Z, T ve S tip üyelik fonksiyonlu) Bulanık
PD kontrolcülerin pozisyon takip performansı değerlendirilmiştir. Çalışmanın
devamında ise, bozucu kuvvetler karşısında önerilen kontrolcülerin
duyarlılığını test etmek için bozuculu basamak ve sinüs eğrisi cevap deneyleri
gerçekleştirilmiştir. Elde edilen deney sonuçları, diğer kontrolcülere göre Bulanık
PD+PID kontrolcünün pozisyon izleme hatalarını daha etkili azaltabildiğini ve dışarıdan
uygulanan bozuculara karşı daha sağlam olduğunu göstermiştir. Ayrıca, pozisyon
takibi deneyleri kapsamında, en başarılı olan Bulanık PD+PID kontrolcü
kullanılarak, gerçek insana ait bilek eklemi pozisyon verileri ile bir deney
daha gerçekleştirilmiş ve VS-AnkleExo robotun Bulanık PD+PID kontrolcü ile
birlikte gerçek insan verilerine dayalı hareket egzersizleri çalışmalarında
kullanılabileceği gösterilmiştir.

Kaynakça

  • [1] Kazerooni H., Steger R. ve Huang L., “Hybrid control of the Berkeley lower extremity exoskeleton (BLEEX)”, The International Journal of Robotics Research, 25(5-6), 561-573, 2006.
  • [2] Neuhaus P.D., Noorden J.H., Craig T.J., Torres T., Kirschbaum J. ve Pratt J.E., “Design and evaluation of Mina: A robotic orthosis for paraplegics”, In Rehabilitation Robotics (ICORR), 2011 IEEE International Conference on (pp. 1-8), 2011.
  • [3] Suzuki K., Mito G., Kawamoto H., Hasegawa Y. ve Sankai Y., “Intention-based walking support for paraplegia patients with Robot Suit HAL”, Advanced Robotics, 21(12), 1441-1469, 2007.
  • [4] Veneman J.F., Kruidhof R., Hekman E.E., Ekkelenkamp R., Van Asseldonk E.H. ve Van Der Kooij H., “Design and evaluation of the LOPES exoskeleton robot for interactive gait rehabilitation”, IEEE Transactions on Neural Systems and Rehabilitation Engineering, 15(3), 379-386, 2007.
  • [5] Van Ham R., Sugar T.G., Vanderborght B., Hollander K.W. ve Lefeber D., “Compliant actuator designs”, IEEE Robotics & Automation Magazine, 16(3), 2009.
  • [6] Migliore S.A., Brown E.A. ve DeWeerth S.P., “Biologically inspired joint stiffness control”, In Robotics and Automation, Proceedings of the 2005 IEEE International Conference on (pp. 4508-4513), 2005.
  • [7] Wang S., Wang L., Meijneke C., Van Asseldonk E., Hoellinger T., Cheron G. ve Tamburella F., “Design and control of the MINDWALKER exoskeleton”, IEEE transactions on neural systems and rehabilitation engineering, 23(2), 277-286, 2015.
  • [8] Kwa H.K., Noorden J.H., Missel M., Craig T., Pratt J.E. ve Neuhaus P.D., “Development of the IHMC mobility assist exoskeleton”, In Robotics and Automation, IEEE International Conference on pp. 2556-2562, 2009.
  • [9] Pratt J.E., Krupp B.T., Morse C.J. ve Collins S.H., “The RoboKnee: an exoskeleton for enhancing strength and endurance during walking”, IEEE international conference on robotics and automation, proceedings, vol. 3, pp 2430–2435, 2004.
  • [10] Cestari M., Sanz-Merodio D., Arevalo J.C., ve Garcia E., “ARES, a variable stiffness actuator with embedded force sensor for the ATLAS exoskeleton”, Industrial Robot: An International Journal, 41(6), 518-526, 2014.
  • [11] Cestari M., Sanz-Merodio D., Arevalo J. C., ve Garcia E., “An adjustable compliant joint for lower-limb exoskeletons”, IEEE/ASME Transactions on Mechatronics, 20(2), 889-898, 2015.
  • [12] Zhu J., Wang Y., Jiang J., Sun B. ve Cao H., “Unidirectional variable stiffness hydraulic actuator for load-carrying knee exoskeleton”, International Journal of Advanced Robotic Systems, 14(1), 1729881416686955, 2017.
  • [13] Vanderborght B., Tsagarakis N. G., Semini C., Van Ham R. ve Caldwell D.G., “MACCEPA 2.0: Adjustable compliant actuator with stiffening characteristic for energy efficient hopping”, In Robotics and Automation, 2009. ICRA'09. IEEE International Conference on (pp. 544-549). IEEE, 2009.
  • [14] Jafari A., Tsagarakis N. G., Sardellitti I., ve Caldwell D.G., “A new actuator with adjustable stiffness based on a variable ratio lever mechanism”, IEEE/ASME Transactions on Mechatronics, 19(1), 55-63, 2014.
  • [15] Liu L., Leonhardt S. ve Misgel B.J., “Design and control of a mechanical rotary variable impedance actuator”, Mechatronics, 39, 226-236, 2016.
  • [16] Sun J., Zhang Y., Zhang C., Guo Z. ve Xiao X., “Mechanical design of a compact Serial Variable Stiffness Actuator (SVSA) based on lever mechanism”, In Robotics and Automation (ICRA), 2017 IEEE International Conference on (pp. 33-38). IEEE, 2017.
  • [17] Tsagarakis N.G., Sardellitti I., ve Caldwell D. G., “A new variable stiffness actuator (CompAct-VSA): Design and modelling”, In Intelligent Robots and Systems (IROS), 2011 IEEE/RSJ International Conference on (pp. 378-383). IEEE, 2011.
  • [18] Dežman M., ve Gams A. “Rotatable cam-based variable-ratio lever compliant actuator for wearable devices”, Mechanism and Machine Theory, 130, 508-522, 2018.
  • [19] Wolf S., ve Hirzinger G., “A new variable stiffness design: Matching requirements of the next robot generation”, In Robotics and Automation, IEEE International Conference on (pp. 1741-1746), 2008.
  • [20] Baser O. ve Kizilhan H., “Mechanical design and preliminary tests of VS-AnkleExo”, Journal of the Brazilian Society of Mechanical Sciences and Engineering, 40(442), 1-16, 2018.
  • [21] Sun J., Guo Z., Sun D., He S., ve Xiao X., “Design, modeling and control of a novel compact, energy-efficient, and rotational serial variable stiffness actuator (SVSA-II)”, Mechanism and Machine Theory, 130, 123-136, 2018.
  • [22] Schiavi R., Grioli G., Sen S. ve Bicchi A., “VSA-II: A novel prototype of variable stiffness actuator for safe and performing robots interacting with humans”, In Robotics and Automation, 2008, IEEE International Conference on (pp. 2171-2176), 2008.
  • [23] Kim B.S. ve Song J.B., “Design and Control of a Variable Stiffness Actuator Based on Adjustable Moment Arm”, IEEE Trans. Robotics, 28(5), 1145-1151, 2012.
  • [24] Zhang C., Liu G., Li C., Zhao J., Yu H. ve Zhu Y., “Development of a lower limb rehabilitation exoskeleton based on real-time gait detection and gait tracking”, Advances in Mechanical Engineering, 8(1), 1687814015627982, 2016.
  • [25] Madani T., Daachi B. ve Djouani K., “Non-singular terminal sliding mode controller: Application to an actuated exoskeleton”, Mechatronics, 33, 136-145, 2016.
  • [26] Cao F., Li C. ve Li Y., “Robust sliding mode adaptive control for lower extremity exoskeleton”, In Chinese Automation Congress (CAC), 2015 (pp. 400-405), 2015.
  • [27] Guo Z., Pan Y., Sun T., Zhang Y. ve Xiao X., “Adaptive neural network control of serial variable stiffness actuators”, Complexity, 2017.
  • [28] Shi P., Lei C., Zhang Y., Wang Y. ve Wang F., “PID control of the mechanical legs based on fuzzy adaptive”, In Cyber Technology in Automation, Control, and Intelligent Systems (CYBER), 2015 IEEE International Conference on (pp. 1965-1970), 2015.
  • [29] Khosla A., Leena G. ve Soni M.K., “Performance evaluation of various control techniques for inverted pendulum”, Performance Evaluation, 3(4), 1096-1102, 2013.
  • [30] Shamaei K., Sawicki G.S. ve Dollar A.M., “Estimation of quasi-stiffness and propulsive work of the human ankle in the stance phase of walking”, PloS one 2013, 8(3), e59935, 2013.
  • [31] Kizilhan H., Baser O., Kilic E. ve Ulusoy N., “Comparison of controllable transmission ratio type variable stiffness actuator with antagonistic and pre-tension type actuators for the joints exoskeleton robots”, In 12th international conference on informatics in control, automation and robotics (ICINCO), vol. 2, pp 188–195, 2015.
  • [32] Pan D., Gao F., Miao Y. ve Cao R., “Co-simulation research of a novel exoskeleton-human robot system on humanoid gaits with fuzzy-PID/PID algorithms”, Advances in Engineering Software, 79, 36-46, 2015.
  • [33] Bovi G., Rabuffetti M., Mazzoleni P. and Ferrarin M., “A multiple-task gait analysis approach: kinematic, kinetic and EMG reference data for healthy young and adult subjects”, Gait & posture, 33(1), 6-13, 2011.
Toplam 33 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Konular Mühendislik
Bölüm Makaleler
Yazarlar

Ergin Kılıç 0000-0002-3099-0303

Bahri Şekerci Bu kişi benim 0000-0002-9762-3073

Hasbi Kızılhan 0000-0001-9433-0171

Özgür Başer 0000-0002-7284-9797

Yayımlanma Tarihi 7 Nisan 2020
Gönderilme Tarihi 1 Şubat 2019
Kabul Tarihi 26 Şubat 2020
Yayımlandığı Sayı Yıl 2020 Cilt: 35 Sayı: 3

Kaynak Göster

APA Kılıç, E., Şekerci, B., Kızılhan, H., Başer, Ö. (2020). Sertliği değiştirilebilir bir ayak bileği dış iskelet robotun çeşitli kontrolcüler ile pozisyon takibi kontrol performansının değerlendirilmesi. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, 35(3), 1551-1564. https://doi.org/10.17341/gazimmfd.520680
AMA Kılıç E, Şekerci B, Kızılhan H, Başer Ö. Sertliği değiştirilebilir bir ayak bileği dış iskelet robotun çeşitli kontrolcüler ile pozisyon takibi kontrol performansının değerlendirilmesi. GUMMFD. Nisan 2020;35(3):1551-1564. doi:10.17341/gazimmfd.520680
Chicago Kılıç, Ergin, Bahri Şekerci, Hasbi Kızılhan, ve Özgür Başer. “Sertliği değiştirilebilir Bir Ayak bileği dış Iskelet Robotun çeşitli kontrolcüler Ile Pozisyon Takibi Kontrol performansının değerlendirilmesi”. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi 35, sy. 3 (Nisan 2020): 1551-64. https://doi.org/10.17341/gazimmfd.520680.
EndNote Kılıç E, Şekerci B, Kızılhan H, Başer Ö (01 Nisan 2020) Sertliği değiştirilebilir bir ayak bileği dış iskelet robotun çeşitli kontrolcüler ile pozisyon takibi kontrol performansının değerlendirilmesi. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi 35 3 1551–1564.
IEEE E. Kılıç, B. Şekerci, H. Kızılhan, ve Ö. Başer, “Sertliği değiştirilebilir bir ayak bileği dış iskelet robotun çeşitli kontrolcüler ile pozisyon takibi kontrol performansının değerlendirilmesi”, GUMMFD, c. 35, sy. 3, ss. 1551–1564, 2020, doi: 10.17341/gazimmfd.520680.
ISNAD Kılıç, Ergin vd. “Sertliği değiştirilebilir Bir Ayak bileği dış Iskelet Robotun çeşitli kontrolcüler Ile Pozisyon Takibi Kontrol performansının değerlendirilmesi”. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi 35/3 (Nisan 2020), 1551-1564. https://doi.org/10.17341/gazimmfd.520680.
JAMA Kılıç E, Şekerci B, Kızılhan H, Başer Ö. Sertliği değiştirilebilir bir ayak bileği dış iskelet robotun çeşitli kontrolcüler ile pozisyon takibi kontrol performansının değerlendirilmesi. GUMMFD. 2020;35:1551–1564.
MLA Kılıç, Ergin vd. “Sertliği değiştirilebilir Bir Ayak bileği dış Iskelet Robotun çeşitli kontrolcüler Ile Pozisyon Takibi Kontrol performansının değerlendirilmesi”. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, c. 35, sy. 3, 2020, ss. 1551-64, doi:10.17341/gazimmfd.520680.
Vancouver Kılıç E, Şekerci B, Kızılhan H, Başer Ö. Sertliği değiştirilebilir bir ayak bileği dış iskelet robotun çeşitli kontrolcüler ile pozisyon takibi kontrol performansının değerlendirilmesi. GUMMFD. 2020;35(3):1551-64.