Electronic components must be tested to allow for safe and reliable missions in radiation environments. The METU Defocusing Beamline (METU-DBL) was installed in the R&D room at the Particle Accelerator Facility (PAF) of Turkish Energy, Nuclear and Mineral Research Agency (TENMAK). This facility was established in accordance with the European Space Agency (ESA), European Space Components Coordination (ESCC), No: 25100 standard to conduct proton irradiation tests for electronic components and various materials to be used in the space environment. METU-DBL uses beam elements such as quadrupole magnets to amplify the beam and collimators to reduce the flux, as per the specifications of the standard.
A pretest setup was constructed, and this system was operated for a total of 17 hours for three months before the METU-DBL final design was assembled. The first protective collimator is made of stainless steel 316L and was used during the period of pretests. As a result of these irradiations, the emerged radioisotopes in the collimator were observed and measured in situ with a NaI detector. These measurements were compared with the FLUKA simulations 120 days after the last irradiation. Among fourteen radioisotopes, only six of them with activity above 1.0×101 Bq/cm3 were matched.

Destekleyen Kurum

Strategy and Budget Presidency

Proje Numarası

2015K121190

Teşekkür

Physics Department of Karadeniz Technical

Kaynakça

  • [1] TAEA, “Proton Accelerator Facility Booklet”, TAEA SANAEM, (2012).
  • [2] ESA, “Single Event Effects Test Method and Guidelines, ESCC Basic Specification No. 25100”, (2014).
  • [3] Demirkoz, M.B., Seckin, C., Avaroglu, A., Bulbul, B., Uslu, P., Kılıç, E., Orhan, Y., Akçelik, S., Saral, Ç., Uzun Duran, S., Kılıç,U., Efthymiopoulos, I.,Poyrazoglu, A.B., Albarodi, A., Celik, N., “Metu-Defocusing Beamline: A 15-30 MeV Proton Irradiation Facility and Beam Measurement System”. EPJ Web of Conferences. EDP Sciences, 225: 01008, (2020).
  • [4] Demirkoz, M.B., Efthymiopoulos, I., Poyrazoglu, A.B., Seckin, C., Uslu, P., Celik, N., Bulbul, B., Albarodi, A., Akçelik, S., Orhan, Y., Avaroglu, A., Kılıç, E., Saral, Ç., Uzun Duran, S., Yiğitoğlu, M., “Installation of the METU Defocusing Beamline to Perform Space Radiation Tests”. In 2019 9th International Conference on Recent Advances in Space Technologies, 355-361, (2019).
  • [5] Grégoire, O., Ladrière, J., “Activation of stainless steel with high energy neutrons.” Journal of Nuclear Materials; 298(3): 309-315, (2001).
  • [6] Uzun Duran, S., Uslu Kiçeci, P., “Demirköz, B. Shield Design of the First Protective Collimator in the METU-Defocusing Beamline (DBL) Project.” Nuclear Technology, 208(2): 364-370, (2022).
  • [7] Battistoni, G., Boehlen, T., Cerutti, F., Chin, P.W., Esposito, L.S, Fassò, A., FerrariA., Lechner A., Empl A., Mairani A., Mereghetti A., Ortega P.G., Ranft J., Roesler S., Sala P.R., VlachoudisV., Smirnov G., “Overview of the FLUKA code” Annals of Nuclear Energy, 82: 10-18, (2015).
  • [8] Ballarini, F., Battistoni, G., Brugger, M., Campanella, M., Carboni, M., Cerutti, F., Empl, A., Fasso, A., Ferrari, A., Gadioli, E., Garzelli, M.V., Lantz, M., Mairani, A., Mostacci, A., Muraro, S., Ottolenghi, A., Patera V., Pelliccioni, M., Pinsky, L.,Ranft, J., Roesler, S., Sala, P.R., Scannicchio, D., Smirnov, G., Sommerer, F., Trovati, S., Villari, R., Vlachoudis, V., Wilson, T., Zapp N., “The physics of the FLUKA code: recent developments”. Advances in Space Research, (2007).
  • [9] Böhlen, T.T., Cerutti, F., Chin, M.P.W., Fassò, A., Ferrari, A., Ortega, P.G., Mairani, A., Sala, P.R., Smirnov, G., Vlachoudis, V., “The FLUKA Code: developments and challenges for high energy and medical applications”. Nuclear Data Sheets, (2014).
  • [10] Collamati, F., An intraoperative Beta-Probe for Cancer Surgery. Switzerland: Springer International Publishing, (2016).
  • [11] Ferrari, A., Sala, P.R., Fasso, A., Ranft, J., FLUKA: A Multi-Particle Transport Code, CERN-2005-010, Geneva, (2011).
  • [12] Canberra Industries, Genie-2000 Spectroscopy System-operations manual, Meriden, USA, (1999).
  • [13] Dizman, S., “Measurement of natural radioactivity level in Rize-centre and towns of Rize”. PhD, Karadeniz Technical University, Trabzon, TURKEY, (2006).
  • [14] https://www.cpp.edu/~pbsiegel/bio431/genergies.html Access date: 1.06.2020.
  • [15] http://www.gammaexplorer.com/wp-content/uploads/2014/03/gammaenergies.pdf Access date: 10.06.2020.
  • [16] http://www.nucleide.org/DDEP_WG/Nuclides/Sn-113_tables.pdf Access date: 10.06.2020.
  • [17] http://www.nucleide.org/DDEP_WG/DDEPdata.htm Access date: 2.06.2020.
  • [18] Sökmen, G., “Cross-Section Measurements of Sc-43 and V-48 Radioisotopes Produced via Bern Medical Cyclotron”. PhD, Middle East Technical University, Ankara, TURKEY, (2017).
  • [19] Hichwa, R.D., Kadrmas, D., Watkins, G.L., Wollenwebe, S, Maniam, S., “Vanadium-48: A renewable source for transmission scanning with PET”. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms; 99(1-4): 804-806, (1995).
  • [20] http://www.old.slcj.uw.edu.pl/~agniecha/por/InSpector100UserManual.pdf. InSpector™ 1000 Digital Hand-Held MCA, User’s Manual.
Yıl 2023, Cilt: 36 Sayı: 4, 1786 - 1793, 01.12.2023
https://doi.org/10.35378/gujs.1018518

Öz

Proje Numarası

2015K121190

Kaynakça

  • [1] TAEA, “Proton Accelerator Facility Booklet”, TAEA SANAEM, (2012).
  • [2] ESA, “Single Event Effects Test Method and Guidelines, ESCC Basic Specification No. 25100”, (2014).
  • [3] Demirkoz, M.B., Seckin, C., Avaroglu, A., Bulbul, B., Uslu, P., Kılıç, E., Orhan, Y., Akçelik, S., Saral, Ç., Uzun Duran, S., Kılıç,U., Efthymiopoulos, I.,Poyrazoglu, A.B., Albarodi, A., Celik, N., “Metu-Defocusing Beamline: A 15-30 MeV Proton Irradiation Facility and Beam Measurement System”. EPJ Web of Conferences. EDP Sciences, 225: 01008, (2020).
  • [4] Demirkoz, M.B., Efthymiopoulos, I., Poyrazoglu, A.B., Seckin, C., Uslu, P., Celik, N., Bulbul, B., Albarodi, A., Akçelik, S., Orhan, Y., Avaroglu, A., Kılıç, E., Saral, Ç., Uzun Duran, S., Yiğitoğlu, M., “Installation of the METU Defocusing Beamline to Perform Space Radiation Tests”. In 2019 9th International Conference on Recent Advances in Space Technologies, 355-361, (2019).
  • [5] Grégoire, O., Ladrière, J., “Activation of stainless steel with high energy neutrons.” Journal of Nuclear Materials; 298(3): 309-315, (2001).
  • [6] Uzun Duran, S., Uslu Kiçeci, P., “Demirköz, B. Shield Design of the First Protective Collimator in the METU-Defocusing Beamline (DBL) Project.” Nuclear Technology, 208(2): 364-370, (2022).
  • [7] Battistoni, G., Boehlen, T., Cerutti, F., Chin, P.W., Esposito, L.S, Fassò, A., FerrariA., Lechner A., Empl A., Mairani A., Mereghetti A., Ortega P.G., Ranft J., Roesler S., Sala P.R., VlachoudisV., Smirnov G., “Overview of the FLUKA code” Annals of Nuclear Energy, 82: 10-18, (2015).
  • [8] Ballarini, F., Battistoni, G., Brugger, M., Campanella, M., Carboni, M., Cerutti, F., Empl, A., Fasso, A., Ferrari, A., Gadioli, E., Garzelli, M.V., Lantz, M., Mairani, A., Mostacci, A., Muraro, S., Ottolenghi, A., Patera V., Pelliccioni, M., Pinsky, L.,Ranft, J., Roesler, S., Sala, P.R., Scannicchio, D., Smirnov, G., Sommerer, F., Trovati, S., Villari, R., Vlachoudis, V., Wilson, T., Zapp N., “The physics of the FLUKA code: recent developments”. Advances in Space Research, (2007).
  • [9] Böhlen, T.T., Cerutti, F., Chin, M.P.W., Fassò, A., Ferrari, A., Ortega, P.G., Mairani, A., Sala, P.R., Smirnov, G., Vlachoudis, V., “The FLUKA Code: developments and challenges for high energy and medical applications”. Nuclear Data Sheets, (2014).
  • [10] Collamati, F., An intraoperative Beta-Probe for Cancer Surgery. Switzerland: Springer International Publishing, (2016).
  • [11] Ferrari, A., Sala, P.R., Fasso, A., Ranft, J., FLUKA: A Multi-Particle Transport Code, CERN-2005-010, Geneva, (2011).
  • [12] Canberra Industries, Genie-2000 Spectroscopy System-operations manual, Meriden, USA, (1999).
  • [13] Dizman, S., “Measurement of natural radioactivity level in Rize-centre and towns of Rize”. PhD, Karadeniz Technical University, Trabzon, TURKEY, (2006).
  • [14] https://www.cpp.edu/~pbsiegel/bio431/genergies.html Access date: 1.06.2020.
  • [15] http://www.gammaexplorer.com/wp-content/uploads/2014/03/gammaenergies.pdf Access date: 10.06.2020.
  • [16] http://www.nucleide.org/DDEP_WG/Nuclides/Sn-113_tables.pdf Access date: 10.06.2020.
  • [17] http://www.nucleide.org/DDEP_WG/DDEPdata.htm Access date: 2.06.2020.
  • [18] Sökmen, G., “Cross-Section Measurements of Sc-43 and V-48 Radioisotopes Produced via Bern Medical Cyclotron”. PhD, Middle East Technical University, Ankara, TURKEY, (2017).
  • [19] Hichwa, R.D., Kadrmas, D., Watkins, G.L., Wollenwebe, S, Maniam, S., “Vanadium-48: A renewable source for transmission scanning with PET”. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms; 99(1-4): 804-806, (1995).
  • [20] http://www.old.slcj.uw.edu.pl/~agniecha/por/InSpector100UserManual.pdf. InSpector™ 1000 Digital Hand-Held MCA, User’s Manual.
Toplam 20 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Mühendislik
Bölüm Physics
Yazarlar

Melahat Bilge Demirköz 0000-0001-7171-5976

Pelin Uslu Kiçeci Bu kişi benim 0000-0001-5271-7554

Selcen Uzun Duran 0000-0003-4943-4654

Proje Numarası 2015K121190
Yayımlanma Tarihi 1 Aralık 2023
Yayımlandığı Sayı Yıl 2023 Cilt: 36 Sayı: 4

Kaynak Göster

APA Demirköz, M. B., Uslu Kiçeci, P., & Uzun Duran, S. (2023). Radioactivation Measurement of a Protective Collimator and Comparisons with Simulation After METU-Defocusing Beamline Pretest Irradiation. Gazi University Journal of Science, 36(4), 1786-1793. https://doi.org/10.35378/gujs.1018518
AMA Demirköz MB, Uslu Kiçeci P, Uzun Duran S. Radioactivation Measurement of a Protective Collimator and Comparisons with Simulation After METU-Defocusing Beamline Pretest Irradiation. Gazi University Journal of Science. Aralık 2023;36(4):1786-1793. doi:10.35378/gujs.1018518
Chicago Demirköz, Melahat Bilge, Pelin Uslu Kiçeci, ve Selcen Uzun Duran. “Radioactivation Measurement of a Protective Collimator and Comparisons With Simulation After METU-Defocusing Beamline Pretest Irradiation”. Gazi University Journal of Science 36, sy. 4 (Aralık 2023): 1786-93. https://doi.org/10.35378/gujs.1018518.
EndNote Demirköz MB, Uslu Kiçeci P, Uzun Duran S (01 Aralık 2023) Radioactivation Measurement of a Protective Collimator and Comparisons with Simulation After METU-Defocusing Beamline Pretest Irradiation. Gazi University Journal of Science 36 4 1786–1793.
IEEE M. B. Demirköz, P. Uslu Kiçeci, ve S. Uzun Duran, “Radioactivation Measurement of a Protective Collimator and Comparisons with Simulation After METU-Defocusing Beamline Pretest Irradiation”, Gazi University Journal of Science, c. 36, sy. 4, ss. 1786–1793, 2023, doi: 10.35378/gujs.1018518.
ISNAD Demirköz, Melahat Bilge vd. “Radioactivation Measurement of a Protective Collimator and Comparisons With Simulation After METU-Defocusing Beamline Pretest Irradiation”. Gazi University Journal of Science 36/4 (Aralık 2023), 1786-1793. https://doi.org/10.35378/gujs.1018518.
JAMA Demirköz MB, Uslu Kiçeci P, Uzun Duran S. Radioactivation Measurement of a Protective Collimator and Comparisons with Simulation After METU-Defocusing Beamline Pretest Irradiation. Gazi University Journal of Science. 2023;36:1786–1793.
MLA Demirköz, Melahat Bilge vd. “Radioactivation Measurement of a Protective Collimator and Comparisons With Simulation After METU-Defocusing Beamline Pretest Irradiation”. Gazi University Journal of Science, c. 36, sy. 4, 2023, ss. 1786-93, doi:10.35378/gujs.1018518.
Vancouver Demirköz MB, Uslu Kiçeci P, Uzun Duran S. Radioactivation Measurement of a Protective Collimator and Comparisons with Simulation After METU-Defocusing Beamline Pretest Irradiation. Gazi University Journal of Science. 2023;36(4):1786-93.