Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2021, , 148 - 160, 30.04.2021
https://doi.org/10.21020/husbfd.761580

Öz

Kaynakça

  • Berthoz, A. (2000). The brain's sense of movement (Vol. 10): Harvard University Press. Bronner, S., Agraharasamakulam, S., & Ojofeitimi, S. (2010). Reliability and validity of electrogoniometry measurement of lower extremity movement. Journal of medical engineering & technology, 34(3), 232-242.

The Validity and Reliability of Knee Joint Position Sense Measurement Performed With Image-Capture Technique in Stroke Patients

Yıl 2021, , 148 - 160, 30.04.2021
https://doi.org/10.21020/husbfd.761580

Öz

Objective: The sense of joint position, which is one of the sub-parameters of proprioception, plays a very important role in initiating and stimulating voluntary and involuntary movements. The ImageJ software program is a free computer program used to make certain measurements on the material photographed in basic medical science laboratories. Angular measurements are also made in the program. In this study, we aimed to use the angular measurement tool to evaluate the sense of joint position in stroke individuals. For this purpose it is investigated the intraexaminer and interexaminer reliability, criterion-related and construct validity of this program in stroke patients.
Material and methods: 50 stroke patients and 51 healthy control groups were included in the study. All stroke patients were assessed in four sessions, with three day intervals. Two fixed physiotherapists performed measurements at different times for the ImageJ software program. The isokinetic measurements were performed on all stroke patients session one. ImageJ software program measurements were carried out once on healthy people with three trials in a session.
Results: The ImageJ software program showed good intraexaminer and interexaminer reliability. In measurements on the stroke patients significant correlations were observed between isokinetic equipment and ImageJ software program for the right and left knee (r=0.77, r=0.77, p<0.001). Measurements of ImageJ software program on both right knee and left knee showed difference between the groups (p=0.045 and p=0.058, respectively).
Conclusion: ImageJ software program is a reliable and valid method to evaluate the knee joint position sense in stroke patients.

Kaynakça

  • Berthoz, A. (2000). The brain's sense of movement (Vol. 10): Harvard University Press. Bronner, S., Agraharasamakulam, S., & Ojofeitimi, S. (2010). Reliability and validity of electrogoniometry measurement of lower extremity movement. Journal of medical engineering & technology, 34(3), 232-242.
Toplam 1 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Sağlık Kurumları Yönetimi
Bölüm Makaleler
Yazarlar

Fatoş Kırteke 0000-0001-9005-3963

Sultan Baştürk Bu kişi benim 0000-0003-3314-3780

Hatice Yağmur Zengin 0000-0002-9855-2449

Fatih Söke Bu kişi benim 0000-0002-8457-1198

Egemen Kızılay Bu kişi benim 0000-0002-4791-370X

Arzu Güçlü Gündüz 0000-0001-8464-1929

Yayımlanma Tarihi 30 Nisan 2021
Gönderilme Tarihi 2 Temmuz 2020
Yayımlandığı Sayı Yıl 2021

Kaynak Göster

APA Kırteke, F., Baştürk, S., Zengin, H. Y., Söke, F., vd. (2021). The Validity and Reliability of Knee Joint Position Sense Measurement Performed With Image-Capture Technique in Stroke Patients. Hacettepe University Faculty of Health Sciences Journal, 8(1), 148-160. https://doi.org/10.21020/husbfd.761580