Optimum insulation thickness to be applied on outer walls using
degree-day (DD) methods for the cities of Tunceli, Hakkâri and Kars was
researched in this study. Total cost and insulation cost were calculated taking
interest and inflation rates into account and the change of these values
depending on insulation thickness was examined. Cost curves were created
according to wall thickness, thermal conduction coefficient of the insulation
material, fuel type and degree-day value and payback periods were calculated.
To minimize heat abductions and to keep the cost at the lowest level, the
effect of insulation in the buildings on energy productivity, health, safety,
comfort and budget. As a result,
while the optimum insulation thickness for Tunceli was obtained to be 7.9 cm,
the optimum insulation thickness for Hakkâri and Kars were obtained to be 8.2 and 10.4 cm.
Bu çalışmada, Tunceli, Hakkâri ve Kars
illeri için derece-gün (DG) yöntemi kullanılarak dış duvarlara uygulanacak
optimum yalıtım kalınlığı araştırılmıştır. Faiz ve enflasyon oranları dikkate
alınarak toplam maliyet ve yalıtım maliyeti hesaplanmış ve bu değerlerin
optimum yalıtım kalınlığı ile değişimi incelenmiştir. Duvar kalınlığına,
yalıtım malzemesinin ısıl iletim katsayısına, yakıt tipine ve derece-gün
değerine göre maliyet eğrileri oluşturulmuş ve geri ödeme süreleri
hesaplanmıştır. Isı kayıplarını en aza indirmek ve maliyeti en düşük düzeyde
tutmak amacıyla, binalarda yapılacak yalıtımın enerji verimliliği, sağlık,
güvenlik, konfor ve bütçe konusunda nasıl bir etkiye sahip olduğu
araştırılmıştır. Neticede Tunceli için optimum yalıtım kalınlığı 7.9 cm hesaplanırken,
Hakkâri ve Kars için 8.2 cm ve 10.4 cm olarak bulunmuştur.