In this study, the effect of the
use of excessive dosages of normal and superplasticizer admixtures on the
compressive strength and absorption properties of concrete was investigated.
Normal plasticizer admixtures were used
0.5 %, 1 %, 5 % and 10 % by weight of cement and superplasticizer
admixtures were used 1.5 %, 3 %, 5 % and
% 10 by weight of cement. Unit weight and slump tests were conducted on the
fresh concretes and compressive strenght and water absorption tests were conducted on the hardened concrete
samples. Test results indicated that the use of excessive dosages of chemical
admixtures significantly decreased compressive strength of concretes and
extended demoulding time. Moreover, the best plasticizer proportion range was
found 1 % - 1.5 %. Furthermore, water absorption values were obtained in the
range of 1.95 % - 5.65 %.
concrete chemical admixture compressive stregth water absorption
Bu çalışmada, 300 ve 450 dozajlı
betonlarda aşırı dozda normal ve süper akışkanlaştırıcı katkı kullanımının
beton basınç dayanımına, su emme yüzdesine etkisi araştırılmıştır. Katkı
miktarları normal akışkanlaştırıcı (NA) katkılarda % 0.5, % 1, % 5 ve % 10,
süper akışkanlaştırıcı (SA) katkılarda ise % 1.5, % 3, % 5 ve % 10 oranlarında
kullanılmıştır. Üretilen bu betonlar üzerinde taze halde iken birim ağırlık ve
çökme deneyleri, sertleşmiş halde iken basınç dayanımı ve su emme deneyi
yapılmıştır. Deney sonuçlarına göre aşırı dozda katkı kullanımının beton basınç
dayanımını ciddi oranda düşürdüğü ve kalıp alma süresini uzattığı görülmüştür.
Basınç dayanımı olarak en ideal katkı yüzdesinin % 1 - % 1.5 arasında olduğu
anlaşılmıştır. Sertleşmiş betonların su emme yüzdesi oranlarının % 1.95 - %
5.65 aralığında olduğu görülmüştür.
Konular | İnşaat Mühendisliği |
---|---|
Bölüm | Araştırma Makaleleri |
Yazarlar | |
Yayımlanma Tarihi | 30 Haziran 2012 |
Yayımlandığı Sayı | Yıl 2012 Cilt: 25 Sayı: 1 |