Assesment of the heart volume using computerized tomography and magnetic resonance imaging

Yıl 2014, Cilt: 31 Sayı: 2, 0 - , 10.09.2014

Öz

Heart volume along with dose volume histograms are essential in reducing pulmonary and cardiac complications. The aim of this study is to measure the ventricular volume using computerized tomography (CT) and magnetic resonance imaging (MRI), to detect the differences between the two scans and to investigate whether the estimated volumes concur with the actual volume of the hearts obtained by the fluid displacement technique. The present study were performed in six heart sheep. Hearts were scanned in the horizontal plane using CT (Toshiba, Aquilion, Japan) and MR machine (Siemens 1.5T Avanto, Germany), we decided for 1 mm as sample thickness fraction for both MR and CT images.The images were analyzed using Image software. Planimetry and threshold stereological methods were applied to estimate the ventricular volume. To evaluate the accuracy of two scans, all the estimates were done by the same observer. The actual hearts mean volumes were 109.38 cm3±17.77. The mean volume of the hearts in CT images of different thickness (0.94, 1.94, 2.94, 3.94 and 4.94 mm) were 110.34 cm3±17.63, 110.61 cm3±17.70, 111.03 cm3±17.65, 111.48 cm3±17.68 and 112.18 cm3±17.86, respectively. The mean volume of the hearts in MRI of different thickness (1.1, 2.1, 3.1, 4.1 and 5.1 mm) were 103.78 cm3±17.60, 104.12 cm3±17.91, 104.31 cm3±17.89, 104.41 cm3±17.84 and 104.56 cm3±17.95, respectively. There were significant statistical difference between the mean volume of the actual hearts and mean volume of the hearts in CT and MRI (p<0.05). CT and MRI datasets allowed an interchangeable utilization of volumetric analysis tools, MRI demonstrated a significant reduction in the ventricular volume, while CT provides accurate volumetric information of the ventricles in comparison withactual hearts volume. However, reliable volumetric analysis was limited to an optimal range of cardiac rates for each modality.

Yıl 2014, Cilt: 31 Sayı: 2, 0 - , 10.09.2014

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Basic Medical Sciences
Yazarlar

Fikri Ozdemır

Micheal Mazonakıs Bu kişi benim

Bunyamin Sahın Bu kişi benim

Amani Elfakı Bu kişi benim

Ozcan Yılmaz Bu kişi benim

Mustafa Bekir Selcuk Bu kişi benim

Yayımlanma Tarihi 10 Eylül 2014
Gönderilme Tarihi 10 Eylül 2014
Yayımlandığı Sayı Yıl 2014 Cilt: 31 Sayı: 2

Kaynak Göster

APA Ozdemır, F., Mazonakıs, M., Sahın, B., Elfakı, A., vd. (2014). Assesment of the heart volume using computerized tomography and magnetic resonance imaging. Journal of Experimental and Clinical Medicine, 31(2). https://doi.org/10.5835/jecm.v2i31.5000068757
AMA Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. Eylül 2014;31(2). doi:10.5835/jecm.v2i31.5000068757
Chicago Ozdemır, Fikri, Micheal Mazonakıs, Bunyamin Sahın, Amani Elfakı, Ozcan Yılmaz, ve Mustafa Bekir Selcuk. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Journal of Experimental and Clinical Medicine 31, sy. 2 (Eylül 2014). https://doi.org/10.5835/jecm.v2i31.5000068757.
EndNote Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB (01 Eylül 2014) Assesment of the heart volume using computerized tomography and magnetic resonance imaging. Journal of Experimental and Clinical Medicine 31 2
IEEE F. Ozdemır, M. Mazonakıs, B. Sahın, A. Elfakı, O. Yılmaz, ve M. B. Selcuk, “Assesment of the heart volume using computerized tomography and magnetic resonance imaging”, J. Exp. Clin. Med., c. 31, sy. 2, 2014, doi: 10.5835/jecm.v2i31.5000068757.
ISNAD Ozdemır, Fikri vd. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Journal of Experimental and Clinical Medicine 31/2 (Eylül 2014). https://doi.org/10.5835/jecm.v2i31.5000068757.
JAMA Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. 2014;31. doi:10.5835/jecm.v2i31.5000068757.
MLA Ozdemır, Fikri vd. “Assesment of the Heart Volume Using Computerized Tomography and Magnetic Resonance Imaging”. Journal of Experimental and Clinical Medicine, c. 31, sy. 2, 2014, doi:10.5835/jecm.v2i31.5000068757.
Vancouver Ozdemır F, Mazonakıs M, Sahın B, Elfakı A, Yılmaz O, Selcuk MB. Assesment of the heart volume using computerized tomography and magnetic resonance imaging. J. Exp. Clin. Med. 2014;31(2).