This study was conducted to compare with rain intensities
and Christiansen’s uniformity coefficients were taken from Veejet spraying
nozzles (80070, 80100 and 80150) by using a laboratory type rain simulator
under different pressures (10, 20, 30 and 40 kPa). Results showed that rain
intensities and Christiansen’s uniformity coefficients increased at Veejet
80070 and 80100 types spraying nozzles, based on increasing pressures. But, it
was found that 30 and 40 kPa pressures effected at Veejet 80150 types spraying
nozzle. Christiansen’s uniformity coefficients were found between 59.85 to
86.68 % in this study.
Rainfall simulator rain intensity Christiansen uniformitiy coefficient pressure
|
Bu çalışma,
laboratuvar tipi yapay yağmurlayıcıda kullanılan Veejet tipi memelerden (80070,
80100 ve 80150) farklı basınçlar altında (10, 20, 30 ve 40 kPa) elde edilen
yağış yoğunluklarını ve Christiansen eş su dağılım katsayılarını kıyaslamak
için yürütülmüştür. Araştırma sonuçları, Veejet 80070 ve 80100 tipi püskürtücü
memelerde basınç artışına bağlı olarak yağış yoğunlukları ve Christiansen eş su
dağılım katsayılarının arttığını göstermiştir. Ancak, Veejet 80150 tipi
püskürtücü memede 30 ve 40 kPa basınçlar etkili olmuştur. Bu çalışmada Christiansen
eş su dağılım katsayıları % 59.85-86.68 arasında bulunmuştur.
Yapay yağmurlayıcı yağış yoğunluğu Christiansen eş su dağılım katsayısı basınç
Birincil Dil | Türkçe |
---|---|
Konular | Mühendislik |
Bölüm | Makaleler |
Yazarlar | |
Yayımlanma Tarihi | 22 Haziran 2016 |
Gönderilme Tarihi | 18 Ocak 2016 |
Kabul Tarihi | 4 Nisan 2016 |
Yayımlandığı Sayı | Yıl 2016 |