Case Report
BibTex RIS Cite

TEMİZ ARALIKLI KATETERE BAĞLI NADİR BİR KOMPLİKASYON: UNUTULMUŞ 'NO TOUCH' MATERYALLERİ

Year 2020, Volume: 3 Issue: 2, 77 - 79, 18.08.2020
https://doi.org/10.33713/egetbd.653768

Abstract

Meningomyelosel tanılı çocukların büyük çoğunluğu nörojenik mesane disfonksiyonuna maruz kalmaktadır. Temiz aralıklı kateterizasyon (TAK) günümüzde bu tür nörojenik mesane disfonksiyonu olan hastaların ürolojik tedavisi için yaygın olarak kullanılmaktadır. Bu olguda meningomyelosel nedeniyle TAK yapmakta olan 17 yaşındaki kız olgunun dirençli idrar yolu enfeksiyonu nedeni ile araştırılmakta iken mesanesinde saptanan ‘no touch-touch free’ katater materyalini raporlamak amaçlanmıştır.

References

  • Lindehall, B, Abrahamsson K, Jodal U ,et.al. Complications of Clean Intermittent Catheterization in Young Females With Myelomeningocele: 10 to 19 Years of Followup. The Journal of Urology 2007; 178(3): 1053–055.
  • Wyndaele, J. Complications of intermittent catheterization: their prevention and treatment. Spinal Cord 2002; 40(10): 536–41
  • Stöhrer M, Castro-Diaz D, Chartier-Kastler E,et.al. Guidelines on neurogenic lower urinary tract dysfunction. Prog Urol. 2007; 17: 703-55.
  • Kibar Y,Demir E, Aydur E, et al. Using Clean Intermittent Catheterization in Urology. Turkish Journal of Urology 2006: 32 (4): 529-32
  • Madersbacher H, Wyndaele JJ, Igawa Y,et al.Conservative management in neuropathic urinary incontinence. Incontinence, 2nd edn. Health Publication Ltd, Plymouth, 2002; 697–754.
  • Wyndaele JJ, Castro D, Madersbacher H, et al. Neurologic urinary and faecal incontinence.. Incontinence, 3rd edn. Health Publication Ltd , Edition 21, Paris, 2005; 1059–162.
  • Sutton G, Shah S, Hill V. Clean intermittent selfcatheterization for quadriplegic patients-a 5 year follow up. Paraplegia 1991;29:542-9.
  • Whitelaw S, Hamonds J, Tregallas R. Clean intermittent self-catheterization in the elderly. Br J Urol 1987;60:125-7.
  • Steven B, Walnut C, Sakti D. Urinary tract infection and intermittent catheterization. Infect Urol 1998;11: 165- 68.
  • .Kuhlemeier KV, Lloyd LK, Stover SL. Localization of upper and lower urinary tract infections in patients with neurogenic bladders. SCI Dig. 1982; 336-42.
  • .Wyndaele JJ: Chronic prostatitis in spinal cord injury patients. Paraplegia. 1985;23: 164-69.
  • Webb R, Lawson A, Neal D. Clean intermittent self-catheterization in 172 adults. Br. J. Urol. 1990;65:20–3.
  • Perrouin-Verbe B, Labat JJ, Richard I, Mauduyt de la Greve I, Buzelin JM, Mathe JF. Clean intermittent catheterization from the acute period in spinal cord injury patients. Long term evaluation of urethral and genital tolerance. Paraplegia 1995;33: 619–24.
  • Amendola MA, Sonda LP, Diokno AC, Vidyasagar M. Bladder calculi complicating intermittent clean catheterization. A J. Roentgenol. 1983;141: 751–3.
  • Morgan JD, Weston PM. The disappearing catheter – a complication of intermittent self-catheterization. Br. J. Urol. 1990; 65: 113– 14.
  • Reisman EM, Preminger GM. Bladder perforation secondary to clean intermittent catheterization. J. Urol. 1989; 142: 1316–17.

A RARE COMPLICATION RELATED TO CLEAN INTERMITTENT CATHETER: FORGOTTEN 'NO TOUCH' MATERIALS

Year 2020, Volume: 3 Issue: 2, 77 - 79, 18.08.2020
https://doi.org/10.33713/egetbd.653768

Abstract

The majority of children with meningomyelocele are exposed to neurogenic bladder dysfunction. Clean intermittent catheterization (CIC) is now widely used for the urological treatment of patients with this type of neurogenic bladder dysfunction. In this case report, we aimed to report 'no touch-touch free’ catheter material detected in the bladder during the investigation of resistant urinary tract infection of a 17-year-old girl with meningomyelocele who performed CIC.

References

  • Lindehall, B, Abrahamsson K, Jodal U ,et.al. Complications of Clean Intermittent Catheterization in Young Females With Myelomeningocele: 10 to 19 Years of Followup. The Journal of Urology 2007; 178(3): 1053–055.
  • Wyndaele, J. Complications of intermittent catheterization: their prevention and treatment. Spinal Cord 2002; 40(10): 536–41
  • Stöhrer M, Castro-Diaz D, Chartier-Kastler E,et.al. Guidelines on neurogenic lower urinary tract dysfunction. Prog Urol. 2007; 17: 703-55.
  • Kibar Y,Demir E, Aydur E, et al. Using Clean Intermittent Catheterization in Urology. Turkish Journal of Urology 2006: 32 (4): 529-32
  • Madersbacher H, Wyndaele JJ, Igawa Y,et al.Conservative management in neuropathic urinary incontinence. Incontinence, 2nd edn. Health Publication Ltd, Plymouth, 2002; 697–754.
  • Wyndaele JJ, Castro D, Madersbacher H, et al. Neurologic urinary and faecal incontinence.. Incontinence, 3rd edn. Health Publication Ltd , Edition 21, Paris, 2005; 1059–162.
  • Sutton G, Shah S, Hill V. Clean intermittent selfcatheterization for quadriplegic patients-a 5 year follow up. Paraplegia 1991;29:542-9.
  • Whitelaw S, Hamonds J, Tregallas R. Clean intermittent self-catheterization in the elderly. Br J Urol 1987;60:125-7.
  • Steven B, Walnut C, Sakti D. Urinary tract infection and intermittent catheterization. Infect Urol 1998;11: 165- 68.
  • .Kuhlemeier KV, Lloyd LK, Stover SL. Localization of upper and lower urinary tract infections in patients with neurogenic bladders. SCI Dig. 1982; 336-42.
  • .Wyndaele JJ: Chronic prostatitis in spinal cord injury patients. Paraplegia. 1985;23: 164-69.
  • Webb R, Lawson A, Neal D. Clean intermittent self-catheterization in 172 adults. Br. J. Urol. 1990;65:20–3.
  • Perrouin-Verbe B, Labat JJ, Richard I, Mauduyt de la Greve I, Buzelin JM, Mathe JF. Clean intermittent catheterization from the acute period in spinal cord injury patients. Long term evaluation of urethral and genital tolerance. Paraplegia 1995;33: 619–24.
  • Amendola MA, Sonda LP, Diokno AC, Vidyasagar M. Bladder calculi complicating intermittent clean catheterization. A J. Roentgenol. 1983;141: 751–3.
  • Morgan JD, Weston PM. The disappearing catheter – a complication of intermittent self-catheterization. Br. J. Urol. 1990; 65: 113– 14.
  • Reisman EM, Preminger GM. Bladder perforation secondary to clean intermittent catheterization. J. Urol. 1989; 142: 1316–17.
There are 16 citations in total.

Details

Primary Language Turkish
Subjects Surgery
Journal Section Case Report
Authors

Mert Hamza Özbilen 0000-0002-5733-6790

Batuhan Ergani 0000-0002-4667-855X

Taha Çetin 0000-0003-0330-4854

Mehmet Yalçın 0000-0001-9943-7453

Yusuf Özlem İlbey 0000-0002-1483-9160

Publication Date August 18, 2020
Acceptance Date May 9, 2020
Published in Issue Year 2020 Volume: 3 Issue: 2

Cite

EndNote Özbilen MH, Ergani B, Çetin T, Yalçın M, İlbey YÖ (August 1, 2020) TEMİZ ARALIKLI KATETERE BAĞLI NADİR BİR KOMPLİKASYON: UNUTULMUŞ ’NO TOUCH’ MATERYALLERİ. Ege Tıp Bilimleri Dergisi 3 2 77–79.

Creative Commons Lisansı


Bu eser Creative Commons Atıf-GayriTicari 4.0 Uluslararası Lisansı ile lisanslanmıştır.


13425                13428            13426            13433            13427